November 2016
Type "FXXX" F aults

Type "FXXX" Faults

DTC
Message on
Number
GCON LCD
F003
F003:SWITCHFAULT
DOWN LIMIT1:Bat+
F007
F007:SWITCHFAULT
CHASSISTILT:Bat+
F012
F012:SENSORFAULT
LEVEL PITCH:Bat+
F013
F013:SENSORFAULT
LEVEL PITCH:Bat-
F014
F014:SENSORFAULT
LEVEL ROLL:Bat+
F015
F015:SWITCHFAULT
LEVEL ROLL:Bat-
F032
F032:SWITCHFAULT
OVLD SWITCH:Bat+
F033
F033:SWITCHFAULT
OVLD:Open/Bat-
F037
F037:SWITCHFAULT
LF RIGGER:Bat+
F039
F039:SWITCHFAULT
RF RIGGER:Bat+
F041
F041:SWITCHFAULT
LR RIGGER:Bat+
F043
F043:SWITCHFAULT
RR RIGGER:Bat+
F045
F045:SWITCHFAULT
LEFT AXLE:Bat+
F047
F047:SWITCHFAULT
RIGHT AXLE:Bat+
Part No. 1272220GT
Description
Short circuit of the down limit #1
switch at system startup.
Short circuit of the Chassis Tilt
Sensor circuit to battery positive.
Short circuit of the Level Pitch
Sensor circuit to battery positive.
Short circuit of the Level Pitch
Sensor circuit to battery negative.
Short circuit of the Level Roll Sensor
circuit to battery positive.
Short circuit of the Level Roll Sensor
circuit to battery negative.
Short circuit of pressure switch to
battery positive.
Open or short circuit of pressure
switch.
Short circuit of the left front outrigger
limit switch to battery positive.
Short circuit of the right front
outrigger limit switch to battery
positive.
Short circuit of the left rear outrigger
limit switch to battery positive.
Short circuit of the right rear
outrigger limit switch to battery
positive.
Short circuit of the left axle
operational limit switch to battery
positive.
Short circuit of the right axle
operational limit switch to battery
positive.
GS-2669 DC • GS-3369 DC • GS-4069 DC
Possible Causes
• Short circuit of the down limit switch circuit.
• Down limit #1 switch short circuit.
• GCON ECM.
• Short circuit in the chassis tilt sensor
• Faulty tilt sensor
• GCON ECM.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the limit switch harness.
• GCON ECM.
• Open or short circuit in the limit switch harness.
• GCON ECM.
• Short circuit of the left front outrigger limit switch.
• Short circuit in outrigger harness.
• GCON ECM.
• Short circuit of the right front outrigger limit switch.
• Short circuit in outrigger harness.
• GCON ECM.
• Short circuit of the left rear outrigger limit switch.
• Short circuit in outrigger harness.
• GCON ECM.
• Short circuit of the right rear outrigger limit switch.
• Short circuit in outrigger harness.
• GCON ECM.
• Short circuit of the left axle operational limit switch.
• Short circuit in axle limit switch harness.
• GCON ECM.
• Short circuit of the right axle operational limit switch.
• Short circuit in axle limit switch harness.
• GCON ECM.
Service and Repair Manual
Fault Codes
Failure Mode
All functions inhibited
except platform down.
All functions inhibited
except platform down.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
Left front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Right front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
Left rear outrigger inhibited
if outrigger extend is
activated.
Outrigger can still be
retracted.
Right rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.