November 2016
10- 2 Outri gger C alibration
10-2

Outrigger Calibration

The Electronic Control Module (ECM) is
programmed to deactivate the drive and steer
functions while the outriggers are deployed and
activate an alarm when a signal is received from
the outrigger level sensor, indicating the outriggers
are not deployed or the machine is out of level.
The ECM is also used to calibrate the outrigger
level sensor to achieve a levelness of 0° +/- 0.5°
front to back and side to side, while the outriggers
are deployed.
For further information or assistance, contact
Genie Product Support.
How to Calibrate the Outrigger
System
1
Move the machine to an area that has a firm,
level surface and is free of obstructions.
2
Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at the platform
controls.
Part No. 1272220GT
GS-2669 DC • GS-3369 DC • GS-4069 DC
Outrigger Components
3
Press and hold the ground control scroll up
and scroll down buttons.
1 scroll down button
2 enter button
3 scroll up button
4 escape button
5 LCD display
4
Pull out the red Emergency Stop button to the
on position at the ground controls.
Result: The ground controls LCD display will
show the following:
5
Release the Scroll Up and Scroll Down
buttons after the ground controller powers up.
6
Use the Scroll Up or Scroll Down buttons to
scroll to Machine Options.
7
Press the Enter button to select Machine
Options.
Service and Repair Manual
85