6-1
Function Manifold Components- Models with Proportional Relief (from
serial number GS6916F-10015)
The function manifold is located inside the hydraulic compartment.
Index
Description
No.
1
Relief valve
2
Accumulator
3
Relief valve
(GS 2669 - 3100 psi / 214 bar)
(GS 3369 - 2900 psi / 200 bar)
(GS 4069 - 2850 psi / 197 bar)
4
Check valve
5
Proportional relief valve
100 - 3500 psi / 7 - 241 bar
6
Relief valve, 1500 psi / 103 bar
7
Check valve
8
Flow control valve 2 gpm / 7.6 L/min
9
Solenoid valve, 3 position 5 way
Check valve
10
Flow control valve, 1 gpm / 3.8 L/min
11
Solenoid Valve, 2 position 3 way
12
Pressure switch
13
Solenoid Valve, 2 position 3 way
Orifice
14
Solenoid Valve, 2 position 3 way
15
Solenoid Valve, 2 position 3 way
16
Solenoid Valve, 2 position 3 way
Part No. 1272220GT
Schematic
Item
FQ
FE
FD
FA
FH
FI
FJ
FK
FL
FM
FG
FF
FN
FB
FC
FP
FO
FR
GS-2669 DC • GS-3369 DC • GS-4069 DC
Service and Repair Manual
Function
Oscillate relief
Oscillate circuit
Lift circuit
Oscillate circuit
System relief
Steer circuit
Load sense
Controls flow to the steer circuit
Steer circuit
Controls flow to the oscillate
circuit
Oscillate circuit
Oscillate / Accumulator
Oscillate / Accumulator
Oscillate / Accumulator
Oscillate right
Lift circuit
Oscillate left
Manifolds
Torque
20 ft-lbs / 27 Nm
11 ft-lbs / 15 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
25 ft-lbs / Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
11 ft-lbs / 15 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
20 ft-lbs / 27 Nm
47