Type "Cxxx" Faults - Genie GS-2669 DC Service And Repair Manual

Serial number range from gs6912-1300/from gs6916f-7897 to gs6916f-10499/from gs69f-10500
Hide thumbs Also See for GS-2669 DC:
Table of Contents

Advertisement

Service and Repair Manual
Fault Codes

Type "CXXX" Faults

Type "CXXX" Faults
DTC
Message on
Number
GCON LCD
C001
C001:GCON ECM
FAULT TYPE 1
C004
C004:GCON ECM
FAULT TYPE 4
C005
C005:GCON ECM
FAULT TYPE 5
C006
C006:GCON ECM
FAULT TYPE 6
C007
C007:GCON ECM
FAULT TYPE 7
C008
C008:GCON ECM
FAULT TYPE 8
C009
C009:GCON ECM
FAULT TYPE 9
C010
C010:SECONDARY
NOT PROGRAMMED
C021
C021:PCON NOT
DETECTED
C023
C023:MACHINE
MODEL FAULT
C025
C025:SYSTEMFAULT
PLAT OVLD:NOCAL
C028
C028:SERVICE
OVERRIDE MODE ON
C029
C029:SYSTEMFAULT
OUTRIGGER:NoCal
C030
C030:DCON RR ECM
FAULT TYPE 01
C031
C031:DCON LR ECM
FAULT TYPE 01
C032
C032:DCON RR ECM
FAULT TYPE 02
C033
C033:DCON LR ECM
FAULT TYPE 02
112
Description
GCON ECM CRC check error.
GCON ECM master switch error.
GCON ECM safety switch error.
GCON input redundancy error.
GCON ECM inter-processor
communication error.
GCON ECM temperature sensor
error.
GCON fault type 9.
Secondary not programmed.
Communication failure between
GCON and PCON.
Discrepancy between model
detected and model programmed.
Platform overload system not
calibrated.
Machine is in service override mode. • Machine programmed for use in service override mode.
Outrigger fault, not calibrated.
Hardware failure of the right rear
drive controller.
Hardware failure of the left rear drive
controller.
Setup initialization failure of the right
rear drive controller at system
startup.
Setup initialization failure of the left
rear drive controller at system
startup.
GS-2669 DC • GS-3369 DC • GS-4069 DC
Possible Causes
• Incorrect software file.
• GCON ECM internal failure.
• Short circuit in the master switch circuit.
• GCON ECM.
• Short circuit in the safety switch circuit.
• GCON ECM.
• Input conditioning circuit failure.
• GCON ECM.
• Incorrectly programmed device.
• Error in loading software on device.
• GCON ECM.
• GCON ECM internal failure.
• GCON ECM.
• Contact Genie support.
• Reinstall software
• Contact Genie support.
• CAN communication failure.
• CAN communication harness.
• PCON disconnected.
• GCON or PCON ECM.
• Incorrect machine model programmed.
• GCON or PCON ECM.
• Platform overload system not calibrated.
• GCON or PCON ECM.
• Calibrate outriggers
• Contact Genie support.
• Right rear DCON ECM.
• Left rear DCON ECM.
• Drive input active at system startup.
• Faulty drive joystick.
• Incorrect software.D14
• Right rear DCON ECM.
• Drive input active at system startup.
• Faulty drive joystick.
• Incorrect software.D14
• Left rear DCON ECM.
November 2016
Failure Mode
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions operate.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited
except for down function
and up function.
Platform can be elevated
only once with the
maximum elevate time of
XX seconds.
Elevate time XX depends
on machine model.
All functions operate. Will
not lift above the down
limit switches.
Performance reduced or
all functions inhibited.
Performance reduced or
all functions inhibited.
Performance reduced or
drive inhibited or all
functions inhibited.
Performance reduced or
drive inhibited or all
functions inhibited.