Genie GS-2669 DC Service And Repair Manual page 71

Serial number range from gs6912-1300/from gs6916f-7897 to gs6916f-10499/from gs69f-10500
Hide thumbs Also See for GS-2669 DC:
Table of Contents

Advertisement

Service and Repair Manual
Manifolds
50 Press the Enter button.
Result: The ground controls LCD display will
show the following:
Note: After 1 second the display will return to
SELECT OPTION, DOWN DELAY.
51 Push in the red Emergency Stop button to the
off position.
52 Perform Maintenance Procedures,
Platform overload System
Switch Decent delay
60
Test the
and
Down Limit
.
GS-2669 DC • GS-3369 DC • GS-4069 DC
How to Adjust the Platform Up
Relief Valve - Models with
Platform Overload and
Proportional Relief
Note: Verify the hydraulic oil level is within the top 2
inches / 5 cm of the sight gauge.
1
Connect a 0 to 5000 psi / 0 to 350 bar
pressure gauge to test port #1 (TP1) on the
function manifold.
1 platform up relief valve
2 test port #1
2
Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at the platform
controls.