Service and Repair Manual
Manifolds
50 Press the Enter button.
Result: The ground controls LCD display will
show the following:
Note: After 1 second the display will return to
SELECT OPTION, DOWN DELAY.
51 Push in the red Emergency Stop button to the
off position.
52 Perform Maintenance Procedures,
Platform overload System
Switch Decent delay
60
Test the
and
Down Limit
.
GS-2669 DC • GS-3369 DC • GS-4069 DC
How to Adjust the Platform Up
Relief Valve - Models with
Platform Overload and
Proportional Relief
Note: Verify the hydraulic oil level is within the top 2
inches / 5 cm of the sight gauge.
1
Connect a 0 to 5000 psi / 0 to 350 bar
pressure gauge to test port #1 (TP1) on the
function manifold.
1 platform up relief valve
2 test port #1
2
Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at the platform
controls.
November 2016
Part No. 1272220GT