Fault Inspection Procedure - Genie GS-2669 DC Service And Repair Manual

Serial number range from gs6912-1300/from gs6916f-7897 to gs6916f-10499/from gs69f-10500
Hide thumbs Also See for GS-2669 DC:
Table of Contents

Advertisement

Service and Repair Manual
Fault Codes
Faul t Ins pec tion Proc edur e

Fault Inspection Procedure

1
OK
Go to step 2
2
Check the harness between the ground controls and the faulted device
OK
Go to step 3
3
100
Check the device associated with the faulted circuit
1
Disconnect the faulted device connector.
2
Using a multi-meter, measure resistance between the two
terminals of the faulted device.
3
Resistance should be as follows.
Device
Solenoid Valve, Drive
Solenoid Valve, Steer
Solenoid Valve, Platform Up
Solenoid Valve, Platform Down
GCON and PCON Alarm
Automotive Horn
Contactor Coil
No Good
1
Disconnect the GCON ECM connectors, C1, C2 and C3.
(or C4 if equipped with outriggers).
2
Disconnect the faulted device connector.
3
Check the continuity between the GCON ECM connector
and the signal side of the faulted device.
 Result: Resistance should be close to 0 Ω.
4
Check the continuity between the return side of faulted
device and system ground.
 Result: Resistance should be close to 0 Ω.
5
Check resistance between return side and signal side of
the harness plug of faulted device.
 Result: Resistance should be 1M Ω or higher.
No Good
Check the GCON ECM
GS-2669 DC • GS-3369 DC • GS-4069 DC
November 2016
Typical Resistance
27.2 Ω
19 Ω
25 Ω
6.25 Ω
>1M Ω
1.0 Ω
47 Ω
Replace faulted device
Replace or repair harness
Part No. 1272220GT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-4069 dcGs-3369 dc

Table of Contents