<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format
(num)(+CSCS)
<oa>
Originating Address
GSM 03.40 TP-Originating-Address Address-Value field in string format; BCD numbers (or GSM default alpha-
bet characters) are converted into characters; type of address given by
(num)
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
(num)
<pages>
Page Parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
(num)
<pdu>
In the case of SMS: GSM 04.11 SC address followed by GSM 03.40 TPDU in hexadecimal format: ME/TA con-
verts each octet of TP data unit into hexadecimal numbers containing two IRA characters (e.g. octet with integer
value 42 is presented to TE as two characters 2A (IRA 50 and 65)). In the case of CBS:
Recipient-Address Ad-dress-Value field in string format; BCD numbers (or GSM default alphabet characters)
are converted into characters; type of address given by
(num)(+CSCS)
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format; BCD numbers (or GSM default alphabet
characters) are converted to characters of the currently selected TE character set (refer to command
AT+CSCS.); type of address given by
(num)(+CSCS)
<sca>
Service Center Address
GSM 04.11 RP SC address Address-Value field in string format; BCD numbers (or GSM default alphabet char-
acters) are converted to characters of the currently selected TE character set (refer to command AT+CSCS); type
of address given by
<tosca>
(num)
<scts>
Service Centre Time Stamp
GSM 03.40 TP-Service-Centre-Time-Stamp in time-string format (refer <dt>)
(num)
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
MC55_ATC_V04.00
Confidential / Released
<tora>
<tora>
Page 333 of 475
<tooa>
GSM 03.40 TP-
<ra>