Siemens Brodersen MC55 AT Command Manual page 223

At command manual
Table of Contents

Advertisement

Write Command
AT^SICS=<conProfileId>, <conParmTag>,
Response(s)
OK
ERROR
+CME ERROR:
<err>
Parameter Description
(num)
<conProfileId>
0...5
(str)
<conParmTag>
Internet connection parameter.
"conType"
"alphabet"
"user"
"passwd"
"apn"
"inactTO"
"calledNum"
"dataType"
"dns1"
MC55_ATC_V04.00
Confidential / Released
<conParmValue>
PIN
!
Internet connection profile identifier.
The
<conProfileId>
when a service profile is created with
to be set as "conId" value of the
Type of Internet connection.
For supported values of
Type>.
Selects the character set for input and output of string parameters within a pro-
file.
The selected value is bound to the specific profile. This means that different
profiles may use different alphabets. Unlike other parameters the alphabet can
be changed no matter whether the
set.
For supported values of
alphabet>.
User name string: maximum 32 characters (where "" is default).
Password string: maximum 32 characters (where ***** is default).
Access point name string value: maximum 100 characters (where "" is default).
Inactivity timeout value in seconds: 0 ... 2
Number of seconds the bearer remains open although the service no longer
needs the bearer connection.
Called BCD number.
Data call type.
For supported values of
dataType>.
Primary DNS server address (IP address in dotted-four-byte format).
This value determines whether to use the DNS server addresses dynamically
assigned by the network or a specific DNS server address given by the user.
"dns1" = "0.0.0.0" (default) means that the CSD or GPRS connection profile
uses dynamic DNS assignment. Any other address means that the Primary
DNS is manually set.
The default value applies automatically if no other address is set. Note that the
read command only returns a manually configured IP address, while
AT^SICS
the value "0.0.0.0" is not indicated at all, no matter whether assumed by default
or explicitly specified.
See also note below.
Page 223 of 475
ASC0 ASC1
MUX1
MUX2
%
%
%
%
identifies all parameters of a connection profile, and,
the
AT^SISS
parameter <srvParmTag>.
AT^SISS
refer to
<conParmValue>
<conParmTag>
<conParmValue>
16
-1, default = 20
<conParmValue>
MUX3 Charge
Last
%
!
!
needs
<conProfileId>
<conParmValue-con-
value "conType" has been
refer to
<conParmValue-
refer to
<conParmValue-
3/17/06
!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brodersen mc55

Table of Contents