At+Cpin2 Pin2 Authentication - Siemens Brodersen MC55 AT Command Manual

At command manual
Table of Contents

Advertisement

5.2

AT+CPIN2 PIN2 Authentication

controls network authentication of the MC55.
AT+CPIN2
The read command returns an alphanumeric string indicating whether or not network authentication is required.
The write command allows the MC55 to store the entered password. This may be for example the SIM PIN2 to
benefit from the features listed below, or the SIM PUK2 to replace a disabled PIN2 with a new one. Note that
PIN2 can only be entered if PIN1 authentication was done.
If the MC55 is requesting SIM PUK2, use
PIN2.
Syntax
Test Command
AT+CPIN2=?
Response(s)
OK
Read Command
AT+CPIN2?
Response(s)
+CPIN2:
<code>
OK
ERROR
+CME ERROR:
<err>
Write Command
AT+CPIN2=<pin>[,
<new
Response(s)
OK
ERROR
+CME ERROR:
<err>
Reference(s)
GSM 07.07
Parameter Description
(str)
<pin>
Password (string type), usually SIM PIN2 or, if requested, SIM PUK2.
(str)
<new pin>
If the requested code was SIM PUK2: new password (PIN2).
See Section 5.1.1,
What to do if PIN or password authentication fails?
need to enter the PUK.
(text)
<code>
READY
SIM PIN2
SIM PUK2
MC55_ATC_V04.00
Confidential / Released
to enter the PUK2, followed by
<pin>
pin>]
PIN
ME is not pending for any password.
ME is waiting for SIM PIN2.
This
is returned only when PIN2 authentication has not yet been done
<code>
or has failed ("+CME ERROR:17").
ME is waiting for SIM PUK2.
This
is returned only when PIN2 authentication has failed and ME is
<code>
pending for SIM PUK2 (i.e. "+CME ERROR:18").
Page 103 of 475
ASC0 ASC1
MUX1
%
%
%
%
for more information about when you may
to specify the new
<new pin>
MUX2
MUX3 Charge
%
%
!
!
Last
!
3/17/06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brodersen mc55

Table of Contents