3-4. Installing the panel
❺
❷
3-5. Installing the foot pedal
A
❹
❸
❶
❻
❶
❷
– 6 –
■ Installing the IP-500
Open cover ❶ and remove cable ❷ once.
1)
As a guide, two perforated holes ❶ (two lo-
cations) have been factory-made on the right-
hand side of the table.
Pass panel cable ❷ through hole ❺ in the
2)
table, and connect the cable to the connector
CN101 ❻ (uppermost connector) of the elec-
trical box.
Install the panel at the position
where X-move cover or head grip
does not interfere with it since
breakage of the panel will be caused.
In the case of two-pedal unit A
1)
Connect connector ❶ of the pedal to connec-
tor CN109 ❹ of the electrical box.
Secure ground wire ❷ of the pedal with set-
screw ❺ that is attached to the electrical box.