Installing The Air Hose - JUKI AMS-221F-2516 Instruction Manual

Ip-500 operation panel
Table of Contents

Advertisement

3-7. Installing the air hose

Close
Open
– 8 –
1)
Connecting the air hose
Connect the air hose to the regulator .
2)
Adjustment of air pressure
Open air cock ❶ , pull up and turn air regula-
tor knob ❷ to adjust the air pressure to 0.5 to
0.55 MPa (for the AMS-221F2516) / 0.35 to
0.4 MPa (for the AMS-221F3020). Then, push
down the knob to fix it.
Close air cock ❶ to expel air.
*
Pull up and turn air regulator knob ❹ of bird's
3)
nest preventing regulator ❸ to adjust the air
pressure to 0.2 to 0.3 MPa. Then, push down
the knob to fix it in that position.