Alcatel-Lucent 1643 AMS Installation Manual page 70

Access multiplexer / access multiplexer small (formerly metropolis am / metropolis ams) release 1.0 through 7.2
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Mechanical installation
Technical data for fan unit
...................................................................................................................................................................................................................................
Overview
The usage of a fan unit is recommended, if sufficient air flow for cooling the 1643 AM
unit cannot be guaranteed. A fan unit is required, if the unit will be mounted in an
outdoor street cabinet, because the fan unit provides sufficient air flow to cool the unit
in a thermally hostile environment such as street cabinets. Proper cooling is ensured as
long as one fan is still working. The fan unit has no air filter and can only be used
together with a DC powered unit.
The following two fan unit types can be used together with a 1643 AM unit:
• CC848841888
• CC848949657.
Specifications
A fan unit has the specifications as given in the table below.
Table 3-2
Size (CC848841888, HxWxD)
Size (CC848949657, HxWxD)
Nominal voltage
Operating voltage range
Air flow
Static air pressure
Nominal power
Operating temp. range
Relative humidity
Absolute humidity
Expected life time
Fuses F1 and F2, marked on
circuit board of the Fan unit
Layout
A fan unit has a power and an alarm interface. The following figure shows the fan unit
with comcode number 848949657. The other fan unit looks similar.
...................................................................................................................................................................................................................................
3-10
Technical specifications (fan unit)
Alcatel-Lucent - Proprietary
See notice on first page
69 mm [2.716"] x 54 mm [2.126"] x 242 mm
[9.527"]
69 mm [2.716"] x 47 mm [1.850"] x 242 mm
[9.527"]
48 VDC
36 to 60 VDC
3
> 1.44 m
/min
70 Pa
10.8 W
–20 ºC ... +70 ºC
10 ... 95 % (non condensing)
3
1 ... 29 g/m
7 years
0.5 A, 125 V, fast
365-312-802R7.2
Issue 4, June 2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1643 am

Table of Contents