Stand-alone test procedures
Procedure
Proceed as follows to perform the optical STM-1 option card test:
...................................................................................................................................................................................................
Assign the installed option card.
1
...................................................................................................................................................................................................
Change the default Alarm Reporting/Severity of the STM1cNES (STM-1 Not Expected
2
Input Signal) alarm from reported "No" to "
...................................................................................................................................................................................................
Provision the following cross-connections:
3
Result:
Port under test
TP2.1
TP2.2
...................................................................................................................................................................................................
Set the PDH analyzer to 2 Mbit/s, 2
4
...................................................................................................................................................................................................
Monitor the analyzer for correct transmission.
5
...................................................................................................................................................................................................
Connect the PDH analyzer to TP1.2.
6
...................................................................................................................................................................................................
Monitor the analyzer for correct transmission.
7
...................................................................................................................................................................................................
Display the raised alarm list on the ITM-CIT, and verify that the requirements
8
mentioned in the table below are met.
Result:
LEDs on the 1643 AM:
Power:
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Yes
Required cross-connections
TP2.1 – LP2.1,1
CC1,1.111 – TP1.1
CC1,1 – LP1.1,1
TP2.2 – LP1.1,2
CC1,2.111 – TP1.2
CC1,2 – LP2.1,2
15–1
PRBS pattern. Connect the analyzer to TP1.1.
Requirements
On
Alcatel-Lucent - Proprietary
See notice on first page
Optical STM-1 option card test
".
7-17