System cabling
Timing interface
...................................................................................................................................................................................................................................
Purpose
The timing interface provides one external timing output for ITU-T compliant 2048
kHz timing signals. It does not support timing inputs.
Connector data
The timing output is realized as 8-pin RJ45 connector suitable for symmetrical twisted
pair cables with an impedance of 120 Ω or coaxial cables with an impedance of 75 Ω.
Figure 4-22 Timing connector
1
Table 4-7
Point on
Connector
Cable data (120 Ω, symmetrical)
Preferably a shielded twisted pair cable should be used (22 or 26 AWG).
Cable data (75 Ω, coaxial)
Preferably a MiniCoax 75Ω 2.5 mm cable should be used.
Cable connection
Please connect the timing cable as shown in the figure below.
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
8
Pin assignment (timing cable)
(120 Ω, symmetrical)
1
TX positive (a-wire)
2
TX negative (b-wire)
3
nc
4
nc
5
nc
6
nc
7
GND
8
GND
Alcatel-Lucent - Proprietary
See notice on first page
Signal Name
Signal Name
(75 Ω, coaxial)
Braid of TX coaxial
nc
Inner conductor of TX coaxial
nc
nc
nc
GND
GND