Alcatel-Lucent 1643 AMS Installation Manual page 222

Access multiplexer / access multiplexer small (formerly metropolis am / metropolis ams) release 1.0 through 7.2
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Link testing
Connecting the fiber cables
...................................................................................................................................................................................................................................
Related information
The fiber cabling within an NE is described in chapter 4, section
(p.
4-49).
Background information
The attenuator which will be determined in the procedure described below should be
placed on the INPUT port because this is the furthest physical point on the fiber line
from the OUTPUT port and takes all connector losses into account.
Before you begin
Be sure that all fiber connectors are clean. A cleaning procedure is described in
Appendix A, section
Procedure
1643 AM/AMS systems operate with invisible laser radiation. Laser radiation can
cause considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector as long
as the optical source is switched on. Always observe the laser warning instructions (cf.
"Laser safety" (p.
Proceed as follows to establish a network:
...................................................................................................................................................................................................
Connect an optical fiber to the OUT port of interface LP1.1 or LP2.1.
1
...................................................................................................................................................................................................
Move to the next NE. At the IN port of the respective optical interface (LP1.1 or
2
LP2.1) measure the received optical power from the far-end transmitter.
Important! The optical power meter must be set to the appropriate wavelength
range.
...................................................................................................................................................................................................................................
8-2
"Fiber cleaning" (p.
DANGER
Laser hazard
1-10)).
Alcatel-Lucent - Proprietary
See notice on first page
B-10).
"Fiber cabling"
365-312-802R7.2
Issue 4, June 2007