Link testing
BER test
...................................................................................................................................................................................................................................
Overview
This test proves the transmission quality of the link by monitoring one VC channel
over a longer period of time.
Estimated duration
Preparation time 5 minutes, test duration 1 hour.
Test setup
The figure below shows a possible test setup.
Figure 8-2 BER test
Remark
Procedure
Proceed as follows to perform a BER test:
...................................................................................................................................................................................................
Connect the SDH/PDH analyzer to 2 Mbit/s tributary port TP1.1. Select a 2
1
test pattern.
...................................................................................................................................................................................................
Make on node A a bi-directional VC-12 cross-connection from TP1.1 to LPx.1,q (x =
2
physical port, q = VC-4 number).
...................................................................................................................................................................................................
Make on node B a bi-directional VC-12 cross-connection from LPy.1,q to a 2 Mbit/s
3
port. Provision an outloop on this 2 Mbit/s port.
...................................................................................................................................................................................................
Start a bit error performance test for 1 hour.
4
...................................................................................................................................................................................................
5
Verify that the requirement mentioned below is met.
...................................................................................................................................................................................................................................
8-6
: Node A is expected to be a 1643 AM/AMS node.
Alcatel-Lucent - Proprietary
See notice on first page
15
-1 PRBS
365-312-802R7.2
Issue 4, June 2007