System cabling
Power interfaces (AMS unit)
...................................................................................................................................................................................................................................
Before you begin
Before connecting any power cables be sure that all circuit breakers which are located
in the external Battery Distribution and Fuse Bay (BDFB) and/or on a Power
Distribution Panel (PDP) are in the
Important! The power cables should be connected later (see section
and testing supply voltage" (p.
DC connector data
The DC connector is a 6-pin terminal block connector with screw down contacts.
Figure 4-4 DC connector (AMS unit)
G
Rab
6
Table 4-2
Point on Connector
AC connector data
The AC connector is a 3-pin IEC 60320 universal connector (input power range: 90 to
264 VAC).
Cable data
Preferably stranded 1.3 mm
Cable connection
The power cables must be connected as shown in the figures below.
NOTE: If an AC/DC converter is used, the DC side needs to be connected to the 1643
AMS and the AC side needs to be connected to a power outlet.
...................................................................................................................................................................................................................................
4-6
Rb
-B
Ra
-A
1
Pin assignment (power cables, AMS unit)
1
2
3
4
5
6
Alcatel-Lucent - Proprietary
position.
OFF
5-3)).
Signal Name
–24/–48/–60 VDC, feed A
DC RTN (return), feed A
–24/–48/–60 VDC, feed B
DC RTN (return), feed B
DC common return for feed A+B
GND (common ground)
2
wires with proper insulation should be used.
See notice on first page
"Switching on
Color
blue
red
blue
red
red
yellow/green
365-312-802R7.2
Issue 4, June 2007