Alcatel-Lucent 1643 AMS Installation Manual page 246

Access multiplexer / access multiplexer small (formerly metropolis am / metropolis ams) release 1.0 through 7.2
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Installation trouble shooting
Backup store state
The state of the backup store can have the following values:
Value
Store Error
Store Clearing
Store Empty
Store Downloading
Store Inactive
...................................................................................................................................................................................................................................
B-8
Description
Memory has corrupted data.
After the download command has been given, the inactive
store is cleared first. When the backup store is in this
state, the NE software download cannot be aborted. To
abort the NE software download, wait until the backup
store state is Store Downloading.
The clearing of the store has been successful and new
software will now be downloaded.
Code is being downloaded to the memory.
Memory contains valid code that is not being executed.
Alcatel-Lucent - Proprietary
See notice on first page
Parameters for NE software installation
365-312-802R7.2
Issue 4, June 2007