19. Amps Info
20. Oil Levels
21. AIF Info
22. Activity Log
23.
Secondary
CNTS
54
For electric fryers, this display shows the present readings from the fryers amps
sensors, which monitor the electrical current supplied to the heaters.
On open fryers, these values indicate the current through each individual heater
coil. on 208 or 240 volt units, this value should be close to the value on the data
plate. On 480 volt fryers, this value should be the value on the data plat
multiplied by 1.76.
The "amps" values should normally cook cycle on and off with the heat on light,
and all three values should be about the same.
Press the program button to continue onto Oil Levels reading.
Displays the status of the ATO (auto top off) system. "FULL" or "LOW is
displayed depending on the ATO status. Press the down arrow one time and
the display shows three readings ex. — 1F, L=314, 315. The — 1F is the
difference between the level probe and the temperature probe if this difference
is — 15 degrees or greater, the vat is low and an "L" is displayed next to this
reading. L=314 is the level sensor reading and 315 is the main temperature
reading in the vat.
Press the program button to continue onto AIF Info.
Information from the AIF (automatic intermittent filtration) board is available in
this step. AIF software is displayed similar to this format: 20:
1 1 . . Press the down arrow and CPU position 1 of 1 displays
2 2 . . Press down again. INP PAN displays. The control displays a "" if the drain
pan is detected and an "X" if the drain pan is not detected.
3 3 . . Press down 3 more times and PAD=XXHR FLTRS=0 displays. The
XXHR displays how long since the last filter envelope replacement. Press
product button 1. to view the date of the last filter change and the 2.
product button to view the time of the last filter change. FLTRS=X tracks
how many filters have been performed since the last filter change.
4 4 . . Press the program button to continue onto Activity Log.
This step for internal use.
Press the program button to continue.
Counts each time secondary contactor is energized.
Press the program button to continue.