How To Perform Zero Load Platform Overload Calibration - Genie S-65 XC Service And Repair Manual

Serial number range from s65xcm-101
Hide thumbs Also See for S-65 XC:
Table of Contents

Advertisement

September 2018
17 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate. The engine should not start or run.
There should be limited APU functionality. The
primary boom up/extend or jib extend should
not operate.
Remove the weight from the platform.
How to Per for m Z ero Load Pl atform Overload C alibration
Part No. 1288652GT
How to Perform Zero Load
Platform Calibration
Perform this procedure when the required weight
for full load calibration is not available. This
procedure will re-calibrate the zero load point
without effecting a previous full load calibration. The
platform load capacity will be reduced until a full
load calibration has been performed. A full load
calibration is required for rated load performance.
Note: Perform this procedure with the machine on a
firm, level surface.
1
Fully retract the boom. Level the platform.
2
Remove all material, tools and equipment from
the platform. Remove the welder, if equipped.
Enter Service Mode. Refer to Repair Procedure,
How to Enter the Service Mode.
3
Press the settings button above the display
and navigate to the Sensor Calibrations menu.
4
Navigate to the Load Sense calibration screen.
5
Select and start the calibration procedure.
6
Follow the on-screen instructions to set the
zero load.
7
Continue to follow the prompts to accept the
weight.
8
The calibration is now complete.
Exit the Service Mode
®
®
S
-60 XC
• S
-65 XC
Service and Repair Manual
Platform Components
Tip-over hazard. Failure to
remove all factory and
non-factory accessories could
result in the machine tipping
over, causing death or serious
injury.
39