Primary Boom Angle Sensor Calibration - Genie S-65 XC Service And Repair Manual

Serial number range from s65xcm-101
Hide thumbs Also See for S-65 XC:
Table of Contents

Advertisement

Service and Repair Manual
Repair Procedures
4-7
Primary Boom Angle Sensor
The primary boom angle sensor is used to limit the
angle of the primary boom relative to the angle of
the turntable and gravity.
How to Calibrate the Primary
Boom Angle Sensor
Note: Perform this procedure with the machine on a
firm, level surface with the boom in the stowed
position.
Note: The turntable level sensor must be calibrated
prior to calibrating the primary boom.
Note: This procedure will establish the cross-check
angle with the boom limit switch LST3S. If LST3S
does not switch its state properly during the
calibration, the calibration will be invalidated.
1
Fully retract and lower the boom. Ensure the
boom is in contact with the boom rest pad.
2
Enter Service Mode. Refer to Repair
Procedure, How to Enter the Service Mode.
3
Press the settings button above the display
and navigate to the Sensor Calibrations menu.
4
Navigate to the Boom Angle Sensor calibration
screen.
5
Select and start the calibration procedure.
6
Start the engine.
60
7
When the display prompts the operator to
lower the boom, press and hold the function
enable button and the boom down buttons until
the display indicates that the lower calibration
point has been obtained. This may require
holding the buttons for several seconds after
the boom has touched the rest pad.
8
Press OK on the display to continue with the
procedure to capture the maximum angle
point.
9
Operate the boom up function until the boom
reaches its maximum angle. Continue holding
the function enable and boom up buttons for
several seconds until the display indicates that
the upper calibration point has been obtained.
This may require holding the buttons for
several seconds after the boom reaches its
maximum angle.
10 Follow the on-screen prompts to lower the
boom until the display indicates the calibration
is complete. If this step isn't done, the boom
will be in the safety envelope when the
calibration procedure ends
11 The calibration is now complete.
12 Exit the Service Mode.
®
®
S
-60 XC
• S
-65 XC