How To Enter Alc600 Software Update Mode - Genie S-65 XC Service And Repair Manual

Serial number range from s65xcm-101
Hide thumbs Also See for S-65 XC:
Table of Contents

Advertisement

Service and Repair Manual
Control System
1-6 H ow to Enter ALC 600 Software U pdate Mode
1-6
How to Enter ALC600 Software
Update Mode
1
Go to the Genie website
http://firmware.genielift.com, select your
machine and ALC600 controller type. Enter
the machine serial number and part number for
the software.
2
Download the software to a USB flash drive. If
zipped, extract the files to the USB flash drive.
3
With the machine off, open the GBOX (ground
box) lid and then remove the four Torx head
screws securing the Display Controller
(DISCON) door and remove the door to
expose the USB port.
1
Insert the flash drive into the USB port.
2
Set keyswitch to ground and pull out the red
ground ESTOP while holding buttons 1 and 4.
3
The Display Controller will go into the
bootloader mode.
4
Browse and select the desired
software. Follow the on-screen guidance to
start the update procedure.
5
When complete, turn off machine.
6
Remove USB flash drive, re-install the Display
Controller door and close the GBOX (ground
box).
7
Power up normally.
8
As the display controller starts, operator shall
verify on the start-up screen that the proper
software and revision are displayed.
9
Perform a function check.
24
®
®
S
-60 XC
• S
-65 XC
September 2018
Part No. 1288652GT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents