Connection

5.8 Connecting the power supply

Additional references
● Guidelines on Handling Electrostatic Sensitive Devices (ESD), see Appendix ESD
Guidelines (Page 139).
● For installing a system with SIMATIC ET 200 I/O (e.g. ET 200S, ET 200M, etc.), refer to
the documentation for the relevant ET 200 I/O systems.
5.8.2

Standards and Regulations

VDE guideline compliance
During wiring, you must observe the appropriate VDE guidelines, in particular VDE 0100 and
VDE 0113 for tripping devices and short-circuit and overload protection.
System start-up after specific events
The following list identifies considerations required for startup of a system following certain
events.
● If the system starts up again following a voltage drop or power failure, all hazardous
operating states must be prevented from occurring. If necessary, force an EMERGENCY
OFF.
● If the system starts up again after the EMERGENCY OFF apparatus is released, the startup
must not be unchecked or undefined.
5.8.3
Connecting the power supply
Connect your power supply (e.g. SITOP smart 24 V / 10 A) directly to the power-supply socket
of the SIMOTION P320‑4.
Figure 5-10
60
24 VDC power supply
Power supply connection
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 01/2015