Siemens SIMOTION P320-4 E Commissioning And Hardware Installation Manual
Siemens SIMOTION P320-4 E Commissioning And Hardware Installation Manual

Siemens SIMOTION P320-4 E Commissioning And Hardware Installation Manual

Hide thumbs Also See for SIMOTION P320-4 E:
Table of Contents

Advertisement

Quick Links

SIMOTION
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual
Valid as of version V4.4
01/2015
Preface
Safety notes
Description
Use planning
Mounting
Connection
Power on and software
installation
Operator Control (hardware)
Parameter assignment/
addressing
Commissioning (software)
Service and maintenance
Alarm, error and system
messages
Troubleshooting/FAQs
Standards and approvals
ESD guidelines
List of abbreviations
1
2
3
4
5
6
7
8
9
10
11
12
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMOTION P320-4 E

  • Page 1 Preface Safety notes Description SIMOTION Use planning SIMOTION P320-4 E / P320-4 S Mounting Connection Commissioning and Hardware Installation Manual Power on and software installation Operator Control (hardware) Parameter assignment/ addressing Commissioning (software) Service and maintenance Alarm, error and system...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    My Documentation Manager Click the following link for information on how to compile documentation individually on the basis of Siemens content and how to adapt it for the purpose of your own machine documentation: http://www.siemens.com/mdm SIMOTION P320-4 E / P320-4 S...
  • Page 4 Preface Training Click the following link for information on SITRAIN - Siemens training courses for automation products, systems and solutions: http://www.siemens.com/sitrain FAQs Frequently Asked Questions can be found in SIMOTION Utilities & Applications, which are included in the scope of delivery of SIMOTION SCOUT, and in the Service&Support pages in Product Support: http://support.automation.siemens.com...
  • Page 5: Table Of Contents

    Decentralized structure......................35 Installing and removing CFast cards..................36 Installing the SIMOTION P320-4 in the control cabinet............39 4.5.1 Notes on installation.......................39 4.5.2 Standard rail mounting......................39 4.5.3 Vertical mounting........................42 Connection..............................45 Connection requirements.......................45 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 6 Requirement...........................74 8.3.2 SIMOTION P Control Manager overview................74 8.3.3 Calling SIMOTION P Control Manager from the control panel..........74 8.3.4 Administration tab........................75 8.3.5 License tab..........................78 Local communication via PC internal..................80 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 7 Restore the factory setting using SIMOTION P State............108 9.8.5.3 Overall reset using SIMOTION P State - operating mode switch setting MRES....108 9.8.5.4 Delete SRAM via SIMOTION P State - button Restart (Del. SRAM)........109 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 8 Standards and approvals..........................137 General rules........................137 ESD guidelines............................139 ESD definition........................139 Electrostatic charging of individuals..................139 Basic measures for protection against discharge of static electricity........140 List of abbreviations..........................141 Commissioning Manual, Abbreviations ................141 Index.................................143 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 9: Safety Notes

    ● Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV (Protective Extra Low Voltage) output voltages for all connections and terminals of the electronics modules. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 10 ● Ensure that smoke can only escape via controlled and monitored paths. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 11 ● Perform a function test. ● Only put your plant into live operation once you have guaranteed that the functions relevant to safety are running correctly. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 12: Safety Instructions For Electromagnetic Fields (Emf)

    – Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring ● Only place electronic components, modules or devices on conductive surfaces (table with ESD surface, conductive ESD foam, ESD packaging, ESD transport container). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 13: Industrial Security

    Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 14 5. Release of environmental pollutants or emissions as a result of improper operation of the system and/or failure to dispose of components safely and correctly. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 15: Specific Safety Instructions For Simotion P320-4

    ● Only install system expansion devices designed for this device. Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. ● Observe the information on electromagnetic compatibility. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 16 ● Remove radiation sources from the environment of the device. ● Switch off radiating devices. ● Reduce the radio output of radiating devices. ● Observe the information on electromagnetic compatibility. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 17: Notes On Use

    ● The correct use of the device has to be verified with a function test on the system. This test can detect programming, configuration and wiring errors. ● Documentation of the test results that you can enter in the relevant safety records when required. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 18 ● Do not obstruct the venting slots of the device. Note Use in an industrial environment without additional protective measures This device was designed for use in a normal industrial environment according to IEC 60721-3-3. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 19: Description

    PLC, motion control and technology functions on account of the increasing use of servo drives: ● Packaging machines ● Plastic and rubber processing machines ● Presses, wire-drawing machines ● Textile machines SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 20: Simotion P320-4 Product Description

    The SIMOTION P320-4 provides high-level industrial performance. It features: ● Compact design ● Maintenance-free operation ● High degree of ruggedness ● Long-term availability Figure 2-1 SIMOTION P320-4 view SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 21: Features

    ● Graphics memory is claimed in main memory (dynamic UMA) Power supply 24 VDC (-20%/+20%) max. 4 A Operating conditions Operation without fan Drives and storage media CFast card or SSD (Solid State Disk) SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 22 3 × RJ45 (100 Mbps) Keyboard, mouse Can be connected via USB interface Software Operating systems P320-4 E Windows Embedded Standard 7 32-bit P320-4 S Windows 7 Ultimate 32-bit SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 23: Simotion P320-4 (Hardware) Structure

    The following figure shows the integration of the SIMOTION P320-4 with integrated PROFINET onboard and optional IsoPROFIBUS board in a target system. Figure 2-3 System overview of the SIMOTION P320-4 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 24: Interfaces And Operating Elements

    SIMOTION SCOUT Engineering System (ES). User data can be stored on the data media of the SIMOTION P320‑4. Siemens WinCC flexible software can be used to visualize operational sequences or to operate the machine. Third-party systems can be linked via the OPC interface.
  • Page 25: Components

    SIMOTION P320‑4. HMI software HMI/Runtime software can be operated on the same PC, e.g. the Siemens WinCC flexible software. Other software packages can be linked by means of the OPC interface. The HMI software is used as the general term in the following.
  • Page 26 SIMOTION for the ET 200M distributed I/O system. For a detailed and routinely updated list of I/O modules enabled with SIMOTION as well as application information, visit us online at: siemens.com - Industry Automation and Drive Technologies - Product Support - Supplementary System Components (http://support.automation.siemens.com/WW/view/en/ 11886029) Further modules are integrated via the GSD file of the device's manufacturer.
  • Page 27: Hmi And Simotion Scout

    See section Local HMI or ES on SIMOTION P320-4 (Page 28) Communication of the HMI / ES via PROFINET / Ethernet / PROFIBUS By using one of these communication variants, you can control and monitor several SIMOTION devices. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 28: Local Hmi Or Es On Simotion P320-4

    SIMOTION P320-4 is already configured for this communication variant at the time of delivery. Figure 2-4 Set PG/PC Interface dialog Note Only HMI-Runtime can be installed on the SIMOTION P320-4 E version. Figure 2-5 Model: Local HMI or ES SIMOTION P320-4 E / P320-4 S...
  • Page 29: Hmi Or Es Via Profinet

    Figure 2-6 Model: Networking via PROFINET References You can find further information on the HMI in the documentation: ● SIMOTION Runtime Basic Functions, section HMI (Human Machine Interface) coupling. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 30: Hmi Or Es Via Ethernet (External Access)

    You can find further information in the documentation for SIMOTION IT: ● SIMOTION IT Diagnostics and Configuration ● SIMOTION IT Programming and Web Services ● SIMOTION IT Virtual Machine and Servlets SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 31: Hmi Or Es Via Isoprofibus (Optional)

    Model: Networking via PROFIBUS DP References You can find further information on the HMI in the documentation: ● SIMOTION Runtime Basic Functions, section HMI (Human Machine Interface) coupling. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 32 Description 2.3 HMI and SIMOTION SCOUT SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 33: Use Planning

    ● Device identification data ● Information about the permitted mounting positions ● Environmental conditions ● Electromagnetic compatibility Link to further information about relevant standards for electromagnetic compatibility (EMC). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 34 Use planning SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 35: Mounting

    The decentralized structure of a panel with the SIMOTION P320-4 can be performed via the display port or DVI connection. Please note the cable lengths that are supported for the panel. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 36: Installing And Removing Cfast Cards

    Only use the CFast card specified with the article number above for the external interface. Requirement ● The device is switched off. ● SIMATIC IPC CFast card, approved for industrial applications. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 37 If you insert a CFast card into a built-in SIMOTION P320-4 in a system, observe the safety regulations for working with electrical systems. Insert the CFast card into the slot, working carefully and without applying excess force. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 38 3. Close and lock the cover. Removal Remove the CFast card from the memory slot by pushing it in until it is ejected by about 5 mm (ball-point pen mechanism). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 39: Installing The Simotion P320-4 In The Control Cabinet

    Mounting the SIMOTION P320-4 on a standard rail Note Use of Siemens 35 mm standard mounting rail is recommended. Mounting the standard mounting rail clip Before you can install the device on a standard mounting rail, you will need to attach the standard mounting rail clip included in the scope of delivery.
  • Page 40 ● 1 T20 screwdriver Use the two screws to mount the standard mounting rail clip on the SIMOTION P320-4 enclosure. Figure 4-1 Mounting the standard mounting rail clip SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 41 Ensure that the locking into place of the SIMOTION P320-4 is audible. Note To ensure secure vertical mounting on standard rails, a standard rail ground terminal should be mounted beneath the device. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 42: Vertical Mounting

    ● Swing the device away from the rails. Additional references Further information on standard rail and vertical mounting can be found in the SIMOTION P320-4 E / P320-4 S Manual. 4.5.3 Vertical mounting The optionally available vertical mounting front kit allows a space-saving installation.
  • Page 43 Article number Scope of deliv‐ Accessories Vertical mounting front kit 6ES7648-1AA20-0YP0 You can order the vertical mounting front kit via the Siemens Industry Mall (http:// www.siemens.com/automation/mall). Additional references Further information on standard rail and vertical mounting can be found in the SIMOTION P320-4 E / P320-4 S Manual.
  • Page 44 Mounting 4.5 Installing the SIMOTION P320-4 in the control cabinet SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 45: Connection

    ● Install the device in such a way that it cannot present a hazard (e.g. by toppling). ● Ensure that the clearance to other components or the sides of cabinets is at least 50 mm above and 100 mm below the device. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 46: Overview Of Connections

    It does not matter in which order connection takes place. The connection of the individual elements is described in the following sections: ● Connecting PROFINET (Page 47) ● Inserting IsoPROFIBUS (Page 50) ● Connecting Ethernet (Page 58) SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 47: Connecting Profinet

    Ethernet cable, where the PROFINET IO with IRT has a reserved area that provides a decoupling from the standard communication. Note PROFINET onboard is not a plug-in board. Instead, it is integrated in the SIMOTION P320‑4. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 48: Connection

    Connection example The figure shows a connection example of a PROFINET application with SIMOTION P320‑4, SINAMICS S120 (CU320-2) and ET 200 PN. Figure 5-2 Example for a PROFINET application SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 49: Mounting A Strain Relief

    For further information see Mounting a strain relief (Page 49). Additional references You can find further information on the website www.siemens.com/simotion (www.siemens.com/simotion): ● Drives and I/O modules that are released for SIMOTION ● You will also find current brochures and catalogs Mounting a strain relief A strain relief for SIMOTION P320-4 is included in the scope of delivery.
  • Page 50: Connecting Profibus

    Only use the enclosed lens head screws for securing the strain relief. Connecting PROFIBUS 5.5.1 Requirement ● SIMOTION P320-4 is switched off and disconnected from the mains ● IsoPROFIBUS board (Article No. 6AU1390-0AA00-0AA1) SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 51: Sync I/O Connecting Cable / Plugging In The Isoprofibus Board

    2. Remove the adhesive tape and change the position of the SYNC I/O connecting cable as follows: the SYNC I/O connecting cable is routed to the interface side of the device and secured there again. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 52 Figure 5-6 Inserting the IsoPROFIBUS board 5. The IsoPROFIBUS board is inserted into the rear PCI slot by applying slight pressure. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 53: Connecting The Isoprofibus Board

    Connecting the IsoPROFIBUS board The interface for the optional IsoPROFIBUS board is protected by a cover. There are two holes in the cover for wiring. Requirement The device is switched off. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 54 The interfaces for the optional IsoPROFIBUS board are then free. 2. Connect the IsoPROFIBUS board to the slots shown. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 55 Connection 5.5 Connecting PROFIBUS 3. Place the cover on the positions shown and close it. Make sure that the latches engage to secure the cover in its position. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 56: Isoprofibus Board And Profibus Dp

    Connecting the bus connectors for the X101 and X102 interfaces (IsoPROFIBUS) The bus connector is used to connect the PROFIBUS cable to the IsoPROFIBUS interface (X101, X102). thus establishing a connection to additional stations. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 57: Profibus Cable

    Permissible cable diameter 8 mm ± 0.5 mm Rules for laying When you install a PROFIBUS cable, you must not: ● Twist ● Stretch ● Or compress it. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 58: Connecting Ethernet

    Order no.: 6XV1850-2H*) ● SIMATIC NET, ind. Ethernet TP CORD RJ45/RJ45, TP CORD assembled with 2 RJ45 connectors Order no.: 6XV1850-2G*) *) Length code Dimensions 0.5 m 10 m SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 59: Connecting The Keyboard And Mouse

    In order to identify hazards, we also recommend that a risk analysis be conducted on the entire system in accordance with the basic safety requirements set out in Appendix 1 of EU machinery directive. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 60: Standards And Regulations

    Connect your power supply (e.g. SITOP smart 24 V / 10 A) directly to the power-supply socket of the SIMOTION P320‑4. ① 24 VDC power supply Figure 5-10 Power supply connection SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 61: Protective Conductor Connection And Potential Equalization

    The protective conductor must not have less than a minimum core cross-section of 2.5 mm ① Protective conductor connection / potential equalization SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 62 Connection 5.8 Connecting the power supply SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 63: Power On And Software Installation

    The SIMOTION P320‑4 responds in this way to every subsequent power-up. Additional software for HMI If required, the following software can be installed directly on the SIMOTION P320-4: ● WinCC flexible ● OPC client from other manufacturers SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 64: Customer-Specific Software

    For this purpose, the system components used are subject to a certification procedure with Siemens as the system manufacturer. The certification process establishes and documents the real-time features of the complete system.
  • Page 65: Operator Control (Hardware)

    The display is done via the application SIMOTION P State. The following images show SIMOTION P State in the started state with/without inserted IsoPROFIBUS board. Figure 7-1 SIMOTION P State - PROFINET onboard SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 66: Led Display

    It is displayed whether the PROFINET interface has been synchron‐ ized. BUS1F Group error An error status is displayed on the IsoPROFIBUS interface (X101). BUS2F Group error An error status is displayed on the IsoPROFIBUS interface (X102). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 67: Mode Selector

    Further information Additional information can be found in the Commissioning and Hardware Installation Manual for SIMOTION P320-4 E / SIMOTION P320-4 S, in the section Memory reset with the mode selector (on the screen) (Page 112). SIMOTION P320-4 E / P320-4 S...
  • Page 68: Current Operating Status

    RUN status: Green STOP status: Yellow NOT STARTED status: Gray Note FAQs can be found in the SIMOTION P320-4 E / P320-4 S Manual in the section Troubleshooting/FAQs. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 69: Function Elements

    SIMOTION P320-4 can be reset to the default settings at the time of delivery (Page 116) via SIMOTION P State. 7.1.6 SIMOTION P State - menus The menus of the SIMOTION P State application are described below: ● SIMOTION P ● Options ● Info SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 70 The temperature specifications for SIMOTION P320-4 can be found under SIMOTION P > Temperature. The current, the minimum and the critical temperature are determined at the housing, mainboard and CPU measuring points and displayed in this dialog box. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 71 Display of software versions. Info about SIMOTION P State Display of the SIMOTION P version. Note The versions in the Info menu only become visible once SIMOTION P320-4 has been started. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 72 Operator Control (hardware) 7.1 SIMOTION P state application SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 73: Parameter Assignment/Addressing

    SIMOTION P Runtime software is handled by the PC's internal communications mechanisms. Further information on how to check the settings in the Windows Control Panel can be found in section Check PC internal settings (Page 80). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 74: Simotion P Control Manager

    Settings > Control Panel). The call can only be made as administrator. If you are not logged on as administrator, a dialog will appear notifying you of this fact. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 75: Administration Tab

    If the call was successful, the SIMOTION P Control Manager dialog, Administration tab, is displayed. The SIMOTION P Control Manager application is in English. 8.3.4 Administration tab The Administration tab contains: ● Startup ● Runtime Network Connections SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 76 The Ethernet interface of the SIMOTION P320-4 is displayed here. It an be addressed via SIMOTION P Runtime. The IP address can be set here, however, it is not permanent. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 77 (Page 83). Click Assign Configuration to also check the settings and accept them in any case. Note The IP data is only displayed when SIMOTION P320-4 is started. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 78: License Tab

    This tab displays the licenses currently installed on this hardware. If you wish to modify the licensing of this hardware, click the Licensing button. The License Manager dialog box is displayed; here you enter a new License Key. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 79 The replacement of the SIMOTION P320‑4 means that the License Keys which were generated for the previous SIMOTION P320‑4 must be regenerated and transferred to the new SIMOTION device. In this case, contact the hotline: http://support.automation.siemens.com Note You must restart the SIMOTION P320‑4 after licensing. To do this, in SIMOTION P State press ●...
  • Page 80: Local Communication Via Pc Internal

    To enable local communication the following settings must have been made: You can access the settings via the Control Panel of Windows: Figure 8-6 Control Panel - Set PG/PC Interface SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 81: Station Configurator

    Station Configurator The Station Configurator is required to configure the communication paths for the HMI software. The Station Configurator is provided directly as desktop icon of the SIMOTION P320-4. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 82 If you want to make changes using the Station Configurator , it is essential that you terminate SIMOTION P before calling the function (with "Terminate SIMOTION P" in the SIMOTION P State application). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 83: Ethernet Communication

    The onboard Ethernet interface must not be deactivated or activated during operation. You connect Industrial Ethernet to the Ethernet interface X1. Industrial Ethernet is a communication network with a transmission rate of 10/100/1000 Mbps. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 84: Ethernet Interface

    Here, however, the IP address can only be changed temporarily. Its validity ends with: – booting, downloading, as well as terminating or restarting of SIMOTION P Runtime. For additional information, refer to section Administration tab (Page 75). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 85 To allows the Windows IP to be accessed externally, this must be set as an exception in the Windows Firewall File and Printer Sharing. Otherwise, there is only limited access to Windows from outside. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 86: Default Ip Addresses For Windows And Simotion P Runtime

    Distribution of the IP addresses for Windows and SIMOTION P Runtime Note If no change of the default IP addresses is desired, all conditions with the default IP addresses are fulfilled and no change is required. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 87 Procedure in HW Config to change the default IP addresses 1. Double-click PNxIE of the PC station. The following dialog box is opened. 2. Click the Properties... button of the Properties - PNxIE dialog box. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 88 (accessible via the Windows Control Panel with Start > Settings > Control Panel). The checkbox Activate Device is displayed after selecting the button for Onboard RT - Ethernet Properties. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 89 Parameter assignment/addressing 8.5 Ethernet communication SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 90: Establishing The Active Flag For An External Pg/Pc

    The PG/PC connection to the configured network is now displayed in bold and yellow. 6. Save the changes via Network > Save and compile and upload them to SIMOTION P320-4. Result Now you can go online via the PG/PC. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 91: Profinet Communication

    When the first warning level is reached, the remaining service life of the battery for buffering CMOS data and buffered SRAM is at least 1 month. Lithium battery - ordering data Designation Article number Further information Lithium battery A5E30314053 Spare part SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 92 Parameter assignment/addressing 8.8 Battery monitoring SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 93: Commissioning (Software)

    ● The installation and parameterization has been completed. ● When networking via PROFINET, the PROFINET addresses of the bus nodes with which the SIMOTION P320-4 communicates are set. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 94: Notes On Commissioning

    3. Prepare the drives for communication on the PROFINET IO. 4. Commission the drives via PROFINET IO. Literature: Function description of the associated drives SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 95: Data Backup

    SIMOTION P320-4. Figure 9-1 Storage media of the SIMOTION P320-4 Drive C: Drive C: reserved for the Windows system software, SIMOTION P kernel, etc. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 96: Simatic Data Backup

    This tool allows the easy backing up and quick restoration of entire memory cards. The SIMATIC IPC Image & Partition Creator only supports the burning of DVD media. This software is available via the online ordering system Siemens Industry Mall (http:// www.siemens.com/industrymall).
  • Page 97: Power-Up Of The Simotion P Kernel

    The restore DVD contains a storage medium image of the plant with which the delivery state of the SIMOTION P320-4 can be restored. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 98 ● Restore a defined state of the machine Advantages ● The user program can use system functions to perform a backup ● Version-independent restoring of the retain data (non-volatile SIMOTION data) Disadvantages No complete backup SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 99: Memory Model

    SIMOTION P320-4 memory model 9.8.3 Project update 9.8.3.1 Overview The backup possibilities described in the following section can be used to update, retransmit or back up a SIMOTION project. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 100: Simotion Project Download Online

    It is essential for the download that the name of the station is identical in the engineering system (SIMOTION SCOUT) and in the Station Configurator of the SIMOTION P320-4. Figure 9-3 SIMOTION SCOUT download from the engineering system SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 101: Simotion Scout - Download Of The Project Data (File Structure)

    SIMOTION P must be in the terminated state for this. Note Note the SIMOTION version The SIMOTION version on the target device must exactly match the version of the device on which the backup was created. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 102: Simotion Scout - Download Of The Project Data With Simotion It (Zip File)

    Settings > [Logon dialog box] > Operation State to Stop > Send a new project (Myproject.ZIP) 3. The unpacking and the import of the data into the user data on the external CFast card is performed automatically. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 103: Backing Up And Restoring Project Data (File Structure)

    Copy the User data directory from a storage medium to the external CFast card (Drive D) of the SIMOTION P320-4 to be newly commissioned. SIMOTION P320-4 must be in the terminated state for this. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 104: Single Backups

    SRAM data will be restored from the backup. If, for example, the SIMOTION P320‑4 needs to be replaced, this backup/restore mechanism allows the data to be transferred to the SIMOTION P320‑4. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 105: Backing Up Non-Volatile Simotion Data (Retain Data)

    ● To restore the retain data via SIMOTION SCOUT, go online and in the menu, run Restore Variables..Restores the saved variables, also over different versions. Figure 9-9 Save retain data SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 106: Restoring Non-Volatile Simotion Data (Retain Data)

    (files on the external CFast card). SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 107: Defined States

    ● Overall reset using SIMOTION P State - operating mode switch setting MRES (Page 108) ● Delete SRAM via SIMOTION P State - button Restart (Del. SRAM) (Page 109) SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 108: Restore The Factory Setting Using Simotion P State

    9.8.5.3 Overall reset using SIMOTION P State - operating mode switch setting MRES An overall reset deletes the non-volatile SIMOTION data or retain data. Figure 9-13 Overall reset SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 109: Delete Sram Via Simotion P State - Button Restart (Del. Sram)

    Figure 9-15 Delete SRAM - Restart (Del. SRAM) If the SIMOTION SCOUT function Target system > Copy RAM to ROM was called previously, the saved project will be reloaded. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 110: Simotion P Overall Reset

    SRAM handling (Page 123). Below is a list of the data that is either capable or not capable of withstanding an overall reset. Data on the external CFast card are retained. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 111 Data not deleted on overall reset The following data is retained: ● Transmission rate ● PROFINET IP address/name of the SIMOTION P320-4 ● IP addresses ● Contents of the diagnostics buffer SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 112: Overall Reset Using The Mode Selector (On Screen)

    3. You must turn the switch back to the MRES position within three seconds. The overall reset will now be performed. The SIMOTION P320‑4 has completed the overall reset when the STOP LED lights up. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 113: Deleting User Data On The Cfast Card

    Applies only for SIMOTION P320-4 E SIMOTION P320-4 E is delivered with deactivated EWF (Enhanced Write Filter). After commissioning the SIMOTION P320-4 E, activate the EWF for drive C, which ensures: ● An extended service life for the CFast card ●...
  • Page 114 When SIMOTION P320-4 powers up again, the backed-up user data will be available once more. This means that SIMOTION P320-4 is ready to run immediately without loss of data, provided that the Windows installation was not damaged by the switch-off. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 115: Service And Maintenance

    You can also use the diagnostic data for diagnostic purposes or forward them to Technical Support for evaluation purposes. Further information SIMOTION P State - menus (Page 69) SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 116: Restoring Factory Settings

    When the factory settings are reset/restored, licenses are retained. 10.2.2 Resetting the SIMOTION P320-4 to the delivery status The SIMOTION P State application is used for this function. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 117: Reset Simotion P320-4 To The Initial State

    SIMOTION P320-4 to its state prior to parameter assignment. Requirements You have saved an image of the memory medium on a remote computer/remote medium. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 118: Installing/Removing Simotion P320-4 Components

    CMOS backup battery 4 years 10.3.2 Replacing the backup battery Note The service life of the backup battery is approximately 5 - 8 years, depending on the environmental conditions. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 119 Battery error entry appears in the diagnostics buffer. Disposal NOTICE Dispose of batteries properly Batteries must be disposed of in accordance with local regulations. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 120 NOTICE Switch off the device before replacing the battery The battery can also be exchanged when the device is operating. However, we recommend switching off the device beforehand. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 121 This can damage the system. Set the device time again. Procedure Steps for replacing the battery: 1. Open the battery compartment. 2. Remove the battery holder. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 122 If the CMOS data has been saved previously with a USER profile, only the date and the time may be set again. All other settings will be made automatically. This means that the default values may not be loaded in this special case. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 123: Special Power-Up Situations

    SRAM backup User data Note "OK"? (storage medium) (storage medium) used "OK"? "OK"? Not applicable Not applicable Board Normal statup Not applicable IMAGE No message box or alarms SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 124 The user data backed up in the SRAM image on the storage medium of the SIMOTION P320‑4 is used. The user data backed up in the SRAM backup on the storage medium of the SIMOTION P320‑4 is used. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 125: After New Installation / Update Of The Simotion P Kernel

    Backup of the user data in the SRAM of the SIMOTION P320‑4 in case of power failure is only guaranteed if the SIMOTION P320‑4 is operated within its defined specifications. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 126 If the hardware of the SIMOTION P320-4 was operated outside of the defined specifications, the user data might not have been backed up in the SRAM of the SIMOTION P320-4 under certain circumstances. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 127: Alarm, Error And System Messages

    I/O devices is running. Bus fault 2 Hz Failure of a connected I/O device. At least one of the assigned I/O devices cannot be addressed. Configuring error. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 128 It is activated in HW Config or in NetPro under the following path: Target system > Ethernet > Edit Ethernet node... via the Browse... button, in the Search Network dialog box via the Flashing button of STEP 7. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 129: Temperature Alarm

    11.2 Temperature alarm For SIMOTION P320‑4, two different temperatures are monitored in the device as regard to whether they reach their respective threshold value. System variables _cpudata.temperature _cpudata.moduletemperature SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 130: Battery Alarm

    In this case, only the retain data for the last back up, normally the last shut down of the SIMOTION P320‑4, is available after the next power-up. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 131: Power Failure / Power Fail

    In these cases, we strongly recommend use of an EWF or a UPS system. Note Applies only for SIMOTION P320-4 E SIMOTION P320-E is delivered with deactivated EWF (Enhanced Write Filter). After the device is commissioned, activate the EWF for drive C: because this ensures: ●...
  • Page 132: Profinet Bus Error Occurs

    Check IP configurations, parameterize required router, etc. 11.6 Under-licensing Error The red system error LED (SF) flashes at 0.5 Hz. Cause No license exists for technology/optional objects under license. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 133: Boot Error Messages

    Possible causes: ● No operating system present ● Incorrect active boot partition ● Wrong drive settings in SETUP Keyboard controller error Controller error. Contact your technical support team. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 134 Alarm, error and system messages 11.7 Boot error messages SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 135: Troubleshooting/Faqs

    SIMOTION P320-4 E / P320-4 S Manual, section Connecting the power supply (24 V DC)). ● Check whether the line side switch is activated (see SIMOTION P320-4 E / P320-4 S Manual, section Operator controls). The monitor remains dark. The monitor is switched Switch on the monitor.
  • Page 136 Troubleshooting/FAQs 12.1 Error correction SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 137: Standards And Approvals

    EMC-compliant configuration of the plant are described in this Manual and/or the "EMC Installation Guideline" Configuration Manual. Please note that ultimately it is always the label on the device that provides the decisive information on the compliance with standards. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 138 Standards and approvals A.1 General rules Declaration of conformity The current Declaration of conformity is available on the Internet at Declaration of conformity. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 139: Esd Guidelines

    This figure indicates the maximum electrostatic charges that can accumulate on an operator when he comes into contact with the indicated materials. These values comply with the specifications in IEC 801-2. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 140: Basic Measures For Protection Against Discharge Of Static Electricity

    If you have to take measurements on a module, make sure that you first discharge any static that may have accumulated in your body. To do this, touch a grounded metal object. Only use grounded measuring instruments. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 141: List Of Abbreviations

    DVI-I Digital Visual Interface Digital display interface with digital and VGA signals Components sensitive to electrostatic charge European standard Enhanced Write Filter Configurable write filter (SIMOTION P320-4 E) Frequently Asked Questions FAQs Ground Chassis ground Human Machine Interface User interface...
  • Page 142 Positive supply voltage of integrated circuits Verein deutscher Elektrotechniker (Union of German Electrical Engineers) Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 143: Index

    User data on the CFast card, 113 SIMOTION P Control Manager, 76 Delete SRAM Communication via SIMOTION P State, 109 Ethernet interface, 86 Delivery condition SIMOTION P320-4, 93 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 144 Backing up, 106 License tab System functions, 107 SIMOTION P Control Manager, 78 Graphics Lithium battery, 119 P320-4, 21 Local HMI / ES Guideline SIMOTION P320-4, 28 ESD, 139 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 145 Overall reset PROFINET connection example Mode selector, 112 SIMOTION P320-4, 48 Retain data, 108 Project data (file structure) SIMOTION P320-4, 111 back up/restore, 103 using SIMOTION P State, 108 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 146 Data deleted on overall reset, 111 SIMOTION P320-4, 80 Data not deleted on overall reset, 111 Setup Data storage concept, 97 SIMOTION P Runtime, 24 Decentralized structure, 35 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 147 SIMOTION P320-4, 63 BIOS Setup, 122 SRAM, 99 back up/restore, 104 Terminate SIMOTION P, 104 SRAM handling, 123, 124 Vertical mounting Standard IE cable types, 49 Accessories, 43 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...
  • Page 148 Web server SIMOTION P State, 70 WinCC flexible, 63 Windows Default IP address, 86 Windows 7 Ultimate 32-bit Data backup, 96 Windows Embedded Standard 7 32-bit Data backup, 96 SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015...

This manual is also suitable for:

Simotion p320-4 s

Table of Contents