4. PARAMETERS
No./symbol/
Setting
name
digit
PT45
HMM
Setting
Home
value
position
3
return method
4
5
6
7
8
11
12
19
20
PT49
Set the rate of change of the torque command per second.
TQS
However, setting "0.0" will disable the torque slope.
Torque slope
This function will be enabled in the profile torque mode.
This parameter corresponds to "Torque slope (Index: 6087h)". When this parameter is mapped to
the link device of CC-Link IE Field Network Basic, the value written with MR Configurator2 is
overwritten by the controller. Thus, do not write a value with MR Configurator2.
Setting range: 0.0 to 1000000.0
PT50
Set the speed of the profile speed command.
PVC
The fractional portion of the parameter will be rounded down.
Profile speed
This function will be enabled in the profile position mode.
command
This parameter corresponds to "Profile velocity (Index: 6081h)". When this parameter is mapped to
the link device of CC-Link IE Field Network Basic, the value written with MR Configurator2 is
overwritten by the controller. Thus, do not write a value with MR Configurator2.
Setting range: 0.00 to instantaneous permissible speed
PT51
Set the maximum profile speed.
MPVC
This function will be enabled in the profile position mode and profile velocity mode.
Maximum
The fractional portion of this parameter will be rounded down in the profile position mode.
profile speed
This parameter corresponds to "Max profile velocity (Index: 607Fh)". When this parameter is
mapped to the link device of CC-Link IE Field Network Basic, the value written with MR
Configurator2 is overwritten by the controller. Thus, do not write a value with MR Configurator2.
Setting range: 0.00 to 20000.00
PT52
Set the maximum speed in the torque control.
VLMT
This function will be enabled in the profile mode.
Speed limit
This parameter corresponds to "Velocity limit value (Index: 2D20h)". When this parameter is
mapped to the link device of CC-Link IE Field Network Basic, the value written with MR
Configurator2 is overwritten by the controller. Thus, do not write a value with MR Configurator2.
Setting range: 0.00 to instantaneous permissible speed
Home position
Home position return
return direction
Address increasing
Method 3
direction
Address increasing
Method 4
direction
Address decreasing
Method 5
direction
Address decreasing
Method 6
direction
Address increasing
Method 7
direction
Address increasing
Method 8
direction
Address decreasing
Method 11
direction
Address decreasing
Method 12
direction
Address increasing
Method 19
direction
Address increasing
Method 20
direction
Function
Setting
method
value
21
22
23
24
27
28
33
34
35
37
4 - 27
Home position
Home position return
return direction
Address decreasing
Method 21
direction
Address decreasing
Method 22
direction
Address increasing
Method 23
direction
Address increasing
Method 24
direction
Address decreasing
Method 27
direction
Address decreasing
Method 28
direction
Address decreasing
Method 33
direction
Address increasing
Method 34
direction
Method 35
Method 37
(Data set type)
Initial
value
[unit]
method
0.0
[%/s]
100.00
[r/min]
20000.00
[r/min]
500.00
[r/min]