Kyocera 13600 Adjustment Manual page 51

Table of Contents

Advertisement

0507: [Developer Exhaust: Result]
Display the result of discharging developer.
If the developer discharge fails, check the displayed code and troubleshoot the problem accordingly. If
countermeasures do not work or a code that is not on the list is displayed, contact your service
representative.
For details about filling/discharging developer, see the Replacement Guide.
Code
Status
1
Succeeded (developer
discharged)
2
Developer not discharged
9
Replenishment quit forcefully
0509: [Developer Setup: Result]
Display the result of developer setup.
If the developer setup fails, check the displayed code and troubleshoot the problem accordingly. If
countermeasures do not work or a code that is not on the list is displayed, contact your service
representative.
For details about filling/discharging developer, see the Replacement Guide.
Code
Status
1
Succeeded
Causes
-
• The developer bottle is
not attached to the
outlet.
• The developer bottle is
attached to the outlet,
but the outlet shutter is
not open.
• The front covers have
been closed.
• The power was turned
off during the
operation.
Causes
-
Setting Values
Solutions
-
Detach the developer bottle,
attach it to the outlet, and
then try the operation again.
Open the front covers, turn
on the main power, and
then try the operation again.
Solutions
-
49

Hide quick links: