4. Details of Menu Items in Advanced Settings
65% of full speed.
• [Reduce Level 3]
50% of full speed.
• The setting will take effect if the ambient temperature is higher than 17°C (62.6°F).
[Reduce Initial CPM: Normal/High Temp.
Environment]
52: [Adjust Cleaning Web Motor Interval]
Specify the interval between each activation of the cleaning web.
You can remove stains from the fusing pressure roller by reducing the interval between each activation
of the cleaning web. However, doing this causes the cleaning web to wear out faster, resulting in more
frequent replacement. If you set this to "0.01", cleaning is always performed during paper feeding.
Press [+] to increase the interval and [−] to reduce it.
Setting Items
[Adjust Cleaning Web Motor Interval]
53: [Adjust Adding Fusing Temperature 1]
Adjust the temperature applied to the fusing unit at the start of paper transfer.
Press [+] to increase the temperature and [−] to reduce it.
Setting Items
[Adjust Adding Fusing Temperature 1]
54: [Adjust Adding Fusing Temperature 2]
Adjust the temperature applied to the fusing unit immediately before the start of paper transfer.
Press [+] to increase the temperature and [−] to reduce it.
128
Setting Items
[Do not Reduce]
[Reduce Level 1]
[Reduce Level 2]
[Reduce Level 3]
Max. Value
Min. Value
3.00
0.01
Max. Value
Min. Value
30
0
Values
Step
Unit
0.01
None
Step
Unit
1
degree(s)