Access Control; B901 Door Controller; Address Settings; Supervision - Bosch B9512G-E Installation Manual

Table of Contents

Advertisement

88
en | Access control
15

Access control

The control panels support up to the following number of modules, cards, and tokens:
Control panel
B9512G
B8512G
Any of the following can grant access:
The control panel access control features can deny access when the system in On (armed).
The control panel can also grant access only to certain authorized users depending on
whether the area is all on, part on, or off. You can also program the system to automatically
turn off (disarm) for authorized users.
The Dual Authentication feature can require a user to enter a passcode and present a card or
token for access.
15.1

B901 door controller

The B901 Access Control Interface Module is a fully supervised, addressable SDI/SDI2 bus
device that allows access control integration for Bosch compatible control panels. This
module offers 14 programmable levels of access authority. Authority for access is controlled
by the user level, the group of the user, the time of day, the door state, and the area armed
state. Control each authority restriction through automatic and manual functions.
The module connects to the control panel with the SDI2 bus or the SDIx bus configured as SDI
using terminals 27 through 30 (or 23 through 26 if configured for SDI2), or using the
interconnect wiring connector. You can connect more than one module to the control panel by
wiring them in series.
For detailed instructions, refer to the corresponding document listed in Related
documentation, page 13.
15.1.1

Address settings

Notice!
The module reads the address switch setting only during module power up. If you change the
setting after you apply power to the module, you must cycle the power to the module in order
for the new setting to take effect.
If multiple access control modules reside on the same system, each access control module
must have a unique address.
For valid addresses, refer to B901 address settings, page 168.
15.1.2

Supervision

With any failure to receive an expected response from the module, all keypads show a system
fault. The control panel sends a module trouble report to the central station (if configured for
module trouble reports).
2018.07 | 10 | F.01U.303.996
B901
32
8
Wiegand-style access control device (card reader) connected to the access control
module
Request to enter (RTE) or request to exit (REX) input
Unlock command on an SDI2 keypad (excluding fire keypads)
D9210C
8 (combine with B901
for a total of 32)
8 (combine with B901
for a total of 8)
Installation Manual
Control Panels
Cards or token
B901. 2,000
D9210C. 999
B901. 500
D9210C. 500
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B9512gB8512g-eB8512g

Table of Contents