Users Menu Parameters; Points Menu Parameters - Bosch B9512G-E Installation Manual

Table of Contents

Advertisement

144 en | Keypad Installer menu
9.
10. Press Edit or Enter to edit the type.
11. Depending on keypad model:
12. Press Save or Enter. The keypad shows Parameter saved.
13. Escape from the menu.
20.1.15

[6] Users menu parameters

In this menu, you can change the Service User passcode and the passcode for User 1.
To add and remove users, change users passcodes, and perform other user functions from the
keypad, you must use the Users menu from the Main menu. Refer to the Control Panels
(B9512G/B8512G/B5512/B4512/B3512) Owner's Manual for more information.
Users (In the Installer menu)
1.
2.
3.
4.
5.
6.
7.
20.1.16

[7] Points menu parameters

Use the parameters in this menu to assign a Point Source and a Point Profile to each point.
The Point Source parameter assigns the point to a device (on-board, Octo-input, and wireless
are examples). The Point Profile determines how the point operates.
Point Source selections
Unassigned
Octo-input
Wireless
On-board
POPEX
*The B426 and the "E" variants do not support IP cameras.
Point Profile selections
Assign a Point Profile to a point by selecting the Point Profile number. The tables below show the Point Profile
number and default configuration for each Point Profile. You must use RPS or the Installer Services Portal
programming tool (available in Europe, Middle East, Africa, and China) to configure the Point Profile parameters.
2018.07 | 10 | F.01U.303.996
Press the icon or softkey for the desired scope.
-or-
Use Previous or Next to go to the desired scope.
Press Save or Enter. The keypad shows Parameter saved and then asks if you would like
to edit the area.
Press the icon or softkey for the desired area.
-or-
Use Previous or Next to go to the desired area.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [6] Users. The keypad shows the Installer passcode.
Use
/Previous or
/Next to toggle between user 000 (service user) and user 001 and
go to the user you want to edit.
Press Edit or Enter to edit the selected user. The curser flashes at the editing location.
Delete existing characters, if necessary, and then enter the new characters.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
ZONEX
Output
Keypad
IP Camera*
Door
Installation Manual
Control Panels
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B9512gB8512g-eB8512g

Table of Contents