Keypad Menu Parameters - Bosch B9512G-E Installation Manual

Table of Contents

Advertisement

Control Panels
1.
2.
3.
4.
5.
6.
Area Account Number
1.
2.
3.
4.
5.
6.
7.
Area Account Name
1.
2.
3.
4.
5.
6.
7.
20.1.14

[5] Keypad menu parameters

The keypad scope defines which areas the keypad affects when armed (on), which areas you
can view with this keypad, and the areas to which this keypad can move. In this menu, you can
choose the keypad's scope. You can also use this menu to identify the keypad type and assign
it to an area.
The control panels provide up to the following number of keypads:
Keypad 1
Bosch Security Systems, Inc.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [4] Areas.
Use
/Previous or
/Next to go to the desired area.
Depending on keypad model:
Press Edit and then Yes or No.
-or-
Press Enter to edit the area and Enter to edit the Area On state for the selected area. Use
Previous or Next to toggle between the Yes and No options.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [4] Areas.
Use
/Previous or
/Next to go to the desired area.
Depending on keypad model:
Press Account # and then Edit.
-or-
Press Enter to edit the area, and then press Next to go to the account number option.
Press Enter to edit the account number for the selected area.
Delete existing characters, if necessary, and then enter the new characters.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [4] Areas.
Use
/Previous or
/Next to go to the desired area.
Depending on keypad model:
Press Account # and then Name and then Edit.
-or-
Press Enter to edit the area, and then press Next and Next to go to the account name
option. Press Enter to edit the account name for the selected area.
Delete existing characters, if necessary, and then enter the new characters.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
B9512G. 32, including up to 16 SDI keypads
B8512G. 16, including up to 16 SDI keypads
Type (Circle one)
No keypad / B91x / B92x / B93x /
B94x / D1255 / D125xRB / D126x
Installation Manual
Keypad Installer menu | en 141
Scope (Circle one)
No Device / Area Wide / Acct Wide /
Panel Wide
2018.07 | 10 | F.01U.303.996

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B9512gB8512g-eB8512g

Table of Contents