(6)
Take out the drum upward.
(7)
Remove 3 screws to take off the flange on
the front side.
(8)
Pull out the drum upward.
<<Precaution when installing the drum
shaft>>
Make sure that the gap plate is not caught
with the drum shaft.
Be sure to install the drum shaft and
cleaner frame without a gap.
No foreign matter must be attached on
the cleaner stay.