8.5

Other errors

1. Operation cannot be performed (operation from the control panel is not successful) after installing
the option(s) such as Wireless LAN module.
-
Check if the optional board is installed properly.
2. The connection to the Wireless LAN cannot be made even though it is set to "Enabled".
-
The connection state and settings of the Wireless LAN can be checked with [USER
FUNCTIONS] → [ADMIN] → [WIRELESS LAN] → [SETTING CHECK].
Confirm the settings with the administrator.
* "NIC INITIALIZING" does not disappear at the time of the power being turned ON and it
disappears after 6 minutes with the NIC initializing time-out. In this case, the connection to the
Wireless LAN did not succeed even though "NIC INITIALIZING" disappears.
* The connection to the Wireless LAN cannot be made if the Access Point to be connected is
not found or security settings are not correct.
3. Abnormality when the power is turned ON
Check that the cable and harness of the fuser unit are not caught.
If the protection function of the fuser unit detects them being caught, the power cannot be turned
ON.