Scanning Section Control Pc Board (Slg) - Toshiba e-STUDIO556 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:
Table of Contents

Advertisement

4.3.11

Scanning section control PC board (SLG)

(1)
Take off the lens cover.
(
P.4-11 "4.3.2 Lens cover")
(2)
Disconnect 10 connectors and remove 4
screws to take off the SLG board.
4.3.12
Carriage wire / Carriage-2
[A] Carriage wire / carriage-2
(1)
Take off the carriage-1.
(
P.4-13 "4.3.5 Carriage-1")
(2)
Attach the wire holder jigs to the pulleys to
prevent the wires from loosening.
Notes:
When the wire holder jig is attached,
make sure that the wire is not shifted or
loosened.
The wire should come out of the slot of
the wire holder jig and be passed under
the arm of it.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
SLG board
Fig. 4-58
Fig. 4-59
Wire holder jig
Wire holder jig
Fig. 4-60
4 - 21
Arm
e-STUDIO556/656/756/856(Ver03)
DISASSEMBLY AND REPLACEMENT
4

Advertisement