Bmc Information - QUANTA QuantaGrid S31A-1U User Manual

Quantagrid series compact 1u server with full feature
Table of Contents

Advertisement

BMC
/SYS/powerSupply
This command provides the specification of the Sensor Type sensor-specific event.
Table 3.7: /SYS/powerSupply
P
N
V
ROPERTY
AME
ALID
Presence*
Power Supply Fail-
ure Detected*
Predictive Fail*
Sensor name list
Power Supply
of power supply
Input Lost (AC/DC)*
All Deasserted
(*Note: Only for
certain models.)
Fully Redundant
Redundancy
Redundancy Lost
*The sensor name list depends on the Server Hardware.
Q&A:
Q1: My system supports two power supply slots and only one power supply unit con-
nected. What is the other power supply status?
A1: The other power supply status is " AllDeasserted ".
Q2: My system supports two power supply slots and two power supply units connected.
But only one power cord plugged. What is the other power supply status?
A2: The other power supply status shows "Presence Detected, Predictive Fail, Power
Supply Input Lost (AC/DC) ".

BMC Information

The BMC level commands provide several options to configure and display parameters of
the management agent.
Table 3.8: Targets and Verbs
R
T
ELATED
ARGETS
CD
/
v
/SP
v
Displays information for the board
V
A
ALUE
CCESS
Presence Detected
indicates the Power Supply Presence detected
Power Supply Failure Detected
indicates the Power Supply Failure detected
Predictive Fail
R
indicates the Power Supply Predictive Failure
Power Supply Input Lost (AC/DC)
indicates the Power Supply input lost, such as power cord not inserted
All Deasserted
indicates the power supply is not inserted
Fully Redundant
Indicates the power redundancy is OK.
Redundancy Lost
R
Indicates the power redundancy is fail. One PSU is removed or AC lost.
na
When system powered off, the state is not available.
EXIT