QUANTA Stratos S810-X52L User Manual

Ultra dense high computing multi-node 2u server

Advertisement

STRATOS S810 Series
S810-X52L
Ultra Dense High Computing
Multi-node 2U Server
User's Guide
Document Version: 1.2.0

Advertisement

Table of Contents
loading

Summary of Contents for QUANTA Stratos S810-X52L

  • Page 1 STRATOS S810 Series S810-X52L Ultra Dense High Computing Multi-node 2U Server User's Guide Document Version: 1.2.0...
  • Page 2 ONVENTIONS Conventions Several different typographic conventions are used throughout Note: this manual. Refer to the following examples for common Highlights general or useful information and tips. usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders, menus, programs, and files.
  • Page 3 CRONYMS Acronyms A signal is deasserted when in the inactive state. Active- low signal names have “_L” appended to the end of the TERM DEFINITION signal mnemonic. Active-high signal names have no “_L” Deasserted Analog to Digital suffix. To reduce confusion when referring to active-high and active-low signals, the terms one/zero, high/low, and ACPI Advanced Configuration and Power Interface...
  • Page 4 CRONYMS IPMI Intelligent Platform Management Interface Node Management In-Target Probe Output buffer 1024 bytes. Original Equipment Manufacturer Keyboard Controller Style Unit of electrical resistance Keyboard, Video, Mouse Power Distribution Board Local Area Network Platform Event Filtering Liquid Crystal Display Platform Event Paging Lower Critical Threshold PERR Parity Error...
  • Page 5 CRONYMS System Event Log SERR System Error A two-wire interface based on the I C protocol. The SMBus SMBus is a low-speed bus that provides positive addressing for devices, as well as bus arbitration Server Management Interrupt. SMI is the highest priority nonmaskable interrupt Server Management Mode Server Management Software...
  • Page 6: Safety Information

    AFETY NFORMATION Safety Information Important Safety Instructions modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Read all caution and safety statements in this document before Electrostatic discharge (ESD) and ESD protection: ESD can performing any of the instructions.
  • Page 7 AFETY NFORMATION...
  • Page 8: Revision History

    CHAPTER UPDATES Copyright Disclaimer Copyright © 2014 Quanta Computer Inc. This publication, The information in this document is subject to change without including all photographs, illustrations and software, is pro- notice. The manufacturer makes no representations or warran- tected under international copyright laws, with all rights ties with respect to the contents hereof and specifically dis- reserved.
  • Page 9: About The Server

    About the Server Chapter 1...
  • Page 10: System Features

    BOUT THE ERVER NTRODUCTION 1.1 Introduction This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing the server chassis. This document provides an overview of the hardware features of the chassis, troubleshooting information, and instructions on how to add and replace components of the multi-node server series.The document also provides information on the BIOS, and Baseboard Management Controller (BMC).
  • Page 11 (optional) (optional) HDD Backplane 1 to 1 PCIe x16 G3 riser slot for low-profile card per node x 1  PCIe Expansion Slot PCIe x16 G3 slot for Quanta LSISAS/RAID or 10GbE SFP+ mezzanine card per node x 1 ...
  • Page 12 Quanta LSISAS 2008 mezzanine card for RAID 0/1/10 Quanta LSISAS 2008 mezzanine card for RAID 0/1/10 Quanta LSISAS2108 PD-8 mezzanine card for RAID 0/1/10/5 (optional)  HW RAID Options Quanta LSISAS2108 PD-8 mezzanine card + LSI RAID 6 Key for RAID 0/1/10/5/6/50/60 (optional)  ® ® ®...
  • Page 13 BOUT THE ERVER YSTEM EATURES Table 1-1: S810-X52L SKU (Continued) S810-X52L 2.5" S810-X52L 2.5" S810-X52L 3.5" S810-X52L 3.5" S810-X52L 1 1G SKU) 1 10G SKU) 1 1G SKU) 1 10G SKU) (1) 1400W high efficiency PSU, 200-240VAC 50/60Hz  Power Supply (1) 1400W high efficiency redundant PSU, 200-240VAC 50/60Hz (optional) ...
  • Page 14: Package Contents

    BOUT THE ERVER ACKAGE ONTENTS 1.1 Package Contents The following list includes the package components for a 2 node configuration: 1 x 2U server chassis  2 x Mainboard modules  2 x Dummy modules  4 x Processor heatsinks ...
  • Page 15: A Tour Of The System

    BOUT THE ERVER OUR OF THE YSTEM 1.1 A Tour of the System The S810-X52L is available as a 2.5” HDD or a 3.5” HDD system. The following illustrations show the major component parts of these two variants. 2.5” HDD System Table 1-2: 2.5”...
  • Page 16 3.5” HDD S BOUT THE ERVER YSTEM 3.5” HDD System Table 1-3: 3.5” System Component Description Item Description PSUs 2 Power supply units (PSU) Chassis System chassis Node Controls and LEDs for system management controller 3.5” HDDs 12 3.5” hard disk drive (HDD) cage Fans Fan module cage PDB boards...
  • Page 17: System Front Features

    BOUT THE ERVER YSTEM RONT EATURES System Front Features Node Control Panels The node control panels manage specific 2.5” and 3.5” HDD groups as indicated in the following illustrations. Note: Each HDD drive group serves a designated mainboard. See “Sys- tem Rear Features”...
  • Page 18 BOUT THE ERVER YSTEM RONT EATURES Node Control Panel Features Table 1-5: Node Control Panel Features (Continued) Feature Function MB2 Power Power On/Off for MB2 Button MB2 ID MB2 module ID LED control Button MB3 Power Power on/off for MB3 Button MB3 ID MB3 module ID LED control...
  • Page 19: System Hdd Sku Introduction

    HDD SKU I BOUT THE ERVER YSTEM NTRODUCTION System HDD SKU Introduction Table 1-6: Node Control Panel LED Description Feature Function Status Description The multi-node systems are available as a 2.5” or 3.5” SKU. Within the HDD array, the HDD enumeration is as follows: MB1 Power Green LED: DC on...
  • Page 20 BOUT THE ERVER YSTEM EATURES System Rear Features S810-X52L Module I/O Features S810-X52L System Rear WARNING! Mainboard combinations other than S810-X52L are not supported. MB 3 TOP PSU MB 1 Figure 1-10. S810-X52L Module I/O Features MB 4 MB 2 BOTTOM PSU Table 1-7: S810-X52L Module I/O Features...
  • Page 21 BOUT THE ERVER YSTEM EATURES S810-X52L Module I/O LED Description Table 1-8: S810-X52L Module I/O LED Description (Continued) Feature Status Description Table 1-8: S810-X52L Module I/O LED Description No link, no access Feature Status Description Green Off Link, no access Identify module by Blue On Right...
  • Page 22: Lan Leds

    BOUT THE ERVER YSTEM EATURES LAN LEDs HDD LED The system mainboard has one I350 or X540 (optional) Ether- Table 1-10: HDD LED Description net controller and two 1GbE or 10GbE (optional) ports. Each SGPIO LED Pattern RJ45 connector has two built-in LEDs. See the following illus- Slot/Device States (RAID States) HDD Access tration and table for details.
  • Page 23: Power Subsystem

    BOUT THE ERVER OWER YSTEM Power Sub-System PSU LED MB 3 TOP PSU MB 1 MB 4 MB 2 BOTTOM PSU Figure 1-12. PSU to Mainboard Module Description WARNING! Figure 1-13. PSU LED Mainboard combinations other than S810-X52L are not supported. Table 1-12: PSU LED Description Feature...
  • Page 24: Cooling Sub-System

    BOUT THE ERVER OOLING YSTEM Cooling Sub-System Fans may spin for some time after the system has been pow- ered off. Allow time for the fans to stop rotating before handling system components. Figure 1-14. Cooling Sub System Table 1-13: Fan Cooling System Feature Description...
  • Page 25: Installation And Assembly Safety Instructions

    Installation and Assembly Safety Installation and Assembly Safety Instructions Instructions Chapter Chapter...
  • Page 26: Installation Assembly Safety Instructions

    NSTALLATION AND SSEMBLY AFETY NSTRUCTIONS NSTALLATION SSEMBLY AFETY NSTRUCTIONS 2.1 Installation Assembly Safety Instructions Guidelines The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply.
  • Page 27 NSTALLATION AND SSEMBLY AFETY NSTRUCTIONS UIDELINES SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps: 1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power button. 3.
  • Page 28 NSTALLATION AND SSEMBLY AFETY NSTRUCTIONS UIDELINES The system is designed to operate in a typical office environment. Choose a site that is: Clean and free of airborne particles (other than normal room dust).  Well ventilated and away from sources of heat including direct sunlight. ...
  • Page 29: Safety Information

    Safety Information Safety Information Chapter Chapter...
  • Page 30: Server Safety Information

    AFETY NFORMATION ERVER AFETY NFORMATION 3.1 Server Safety Information To reduce the risk of bodily injury, electrical shock, fire, and symbols may be used throughout the documentation and may equipment damage, read this document and observe all warn- be marked on the product and / or the product packaging. ings and precautions in this guide before installing or maintain- ing your server product.
  • Page 31: Intended Application Uses

    AFETY NFORMATION NTENDED PPLICATION test equipment), other than an ITE application, may require fur- ther evaluation. Please recycle battery. Site Selection The rail racks are designed to carry only the weight of the server system. Do not use rail-mounted equipment as a workspace. Do not place additional The system is designed to operate in a typical office environ- load onto any rail-mounted equipment.
  • Page 32: Equipment Handling Practices

    AFETY NFORMATION QUIPMENT ANDLING RACTICES Equipment Handling Practices CAUTION! HE POWER SUPPLY IN THIS PRODUCT CONTAINS NO USER SERVICE Reduce the risk of personal injury or equipment damage: ABLE PARTS O NOT OPEN THE POWER SUPPLY AZARDOUS VOLT CURRENT AND ENERGY LEVELS ARE PRESENT INSIDE THE POWER Conform to local occupational health and safety require- ...
  • Page 33: System Access Warnings

    AFETY NFORMATION YSTEM CCESS ARNINGS System Access Warnings CAUTION! HE POWER CORD MUST HAVE SAFETY GROUND PIN OR CONTACT THAT IS SUITABLE FOR THE ELECTRICAL OUTLET CAUTION! O AVOID PERSONAL INJURY OR PROPERTY DAMAGE THE FOLLOWING SAFETY INSTRUCTIONS APPLY WHENEVER ACCESSING THE INSIDE OF CAUTION! THE PRODUCT HE POWER SUPPLY CORD...
  • Page 34: Rack Mount Warnings

    AFETY NFORMATION OUNT ARNINGS accessible, and it must be labeled as controlling power to the CAUTION! entire unit, not just to the server(s). NLESS YOU ARE ADDING OR REMOVING A HOT PLUG COMPONENT ALLOW THE SYSTEM TO COOL BEFORE OPENING THE COVERS To avoid risk of potential electric shock, a proper safety ground AVOID THE POSSIBILITY OF COMING INTO CONTACT WITH HOT COMPO must be implemented for the rack and each piece of equipment...
  • Page 35: Electrostatic Discharge (Esd)

    (ESD) AFETY NFORMATION LECTROSTATIC ISCHARGE Particular attention should be gi v en to supply connections other CAUTION! than direct connections to the branch circuit (e.g. use of power ISPOSE OF BATTERIES ACCORDING TO LOCAL ORDINANCES AND REG strips). ULATIONS Electrostatic Discharge (ESD) CAUTION! O NOT ATTEMPT TO RECHARGE A BATTERY CAUTION!
  • Page 36: Laser Peripherals Or Devices

    AFETY NFORMATION THER AZARDS Laser Peripherals or Devices CAUTION! O AVOID RISK OF RADIATION EXPOSURE AND OR PERSONAL INJURY Do not open the enclosure of any laser peripheral or device  Laser peripherals or devices are not serviceable  Return to manufacturer for servicing. ...
  • Page 37: Regulatory And Compliance Information

    Regulatory and Compliance Regulatory and Compliance Information Information Chapter Chapter...
  • Page 38: Product Regulatory Compliance Markings

    EGULATORY AND OMPLIANCE NFORMATION RODUCT EGULATORY OMPLIANCE ARKINGS 4.1 Product Regulatory Compliance Markings This product is marked with the following Product Certification Table 10-1: Product Regulatory Compliance Markings (Continued) markings: Table 10-1: Product Regulatory Compliance Markings BSMI Certifi- EGULATORY cation Num- EGION ARKING R43039...
  • Page 39: Electromagnetic Compatibility Notices

    EGULATORY AND OMPLIANCE NFORMATION LECTROMAGNETIC OMPATIBILITY OTICES 4.2 Electromagnetic Compatibility Notices FCC Verification Statement (USA) Consult the dealer or an experienced radio/TV technician  for help. This device complies with Part 15 of the FCC Rules. Operation Any changes or modifications not expressly approved by the is subject to the following two conditions: (1) this device may grantee of this device could void the user's authority to operate not cause harmful interference, and (2) this device must accept...
  • Page 40: Regulated Specified Components

    VCCI (J EGULATORY AND OMPLIANCE NFORMATION APAN VCCI (Japan) Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated com- ponents must be used and conditi o ns adhered to. Interchanging or use of other component will void the UL listing and other product certifications and approvals.
  • Page 41: Restriction Of Hazardous Substances (Rohs) Compliance

    OMPLIANCE Restriction of Hazardous Substances (RoHS) Compliance Quanta® Computer Inc. has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable threshold limits or (2) an approved / pending RoHS exemption applies.