7.7.6

Grounding the Installation

CAUTION: The Outdoor Unit (ODU) must be properly grounded to protect against power
surges. It is the user's responsibility to install the equipment in accordance with Section 810
of the National Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the National Electrical
Code in the country of installation. These codes describe correct installation procedures for
grounding the outdoor unit, mast, lead-in wire and discharge unit, size of grounding
conductors and connection requirements for grounding electrodes. It is recommended that
installation of the outdoor unit be contracted to a professional installer.
7.7.7

Making the ODU Connection at the PTP 300/500/600 Series Bridge PIDU Plus

The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45
connection has been placed inside the PIDU Plus hinged cover to prevent the user from
inadvertently plugging other equipment into the ODU RJ45 socket.
CAUTION: Plugging other equipment into the ODU RJ45 socket may damage the equipment
due to the non-standard techniques employed to inject DC power into the 100BaseT
connection between the PIDU Plus and the ODU. Plugging the ODU into other equipment
may damage the ODU and/or the other equipment.
Step 1: Undo the retaining screw and
hinge back the cover.
Step 3: Replace the cover and secure with the retaining screw
Step 2: Plug in the ODU into the PIDU Plus Cable
ensuring that it snaps home
65
7 Installation