10.1.3 Checking your wiring

If the above procedures fail to diagnose the issue you may have a wiring fault. Unplug the
RJ45 from the PIDU+ and check the following resistances at the RJ45:
1. Check the cable resistance between pins 1 & 2, 3 & 6, 4 & 5 and 7 & 8 at the RJ45.
2. Check against column 2 in Table 23. Resistances for each pair should be within 1 ohm of
each other.
3. Check the cable resistance between pins 1 & 3 at the RJ45. Check against column 3 in
Table 23.
Yellow LED No Ethernet
Green LED
Cable Connected
Off
Off
Will flash once per second
regularly approximately 30
On
seconds after power
applied for 10 seconds then
will go out and stay out
On
N/A
On
N/A
Off while switch pressed.
Approximately 30 seconds after releasing the
switch, flashes twice per second regularly for 10
On
seconds, then boots in "Recovery Mode".
While in "Recovery Mode" the unit will only be
accessible via the IP address 169.254.1.1.

Table 22 - Power Indoor Unit LED check chart

152
10 Fault Finding
Yellow LED
Ethernet Cable
Connected between
PIDU Plus and
NIC/Switch/Hub
Off
Will flash once per
second regularly
approximately 30
seconds after power
applied for 10
seconds then operate
as Ethernet
Link/Activity LED
Will be on solid for a
valid link.
Will be on solid, but
will blink randomly as
traffic passes through