Spectrum Management; Figure 57 - Reboot Confirmation Pop Up - Motorola PTP 58500 User Manual

Ptp 500 series point-to-point wireless bridges
Hide thumbs Also See for PTP 58500:
Table of Contents

Advertisement

When the software image has been written to non-volatile memory Figure 56 will be displayed
showing the status of the software upload.
Reboot the unit by clicking the "Reboot Wireless Unit" button. You will be asked to confirm
this action as shown in Figure 57.
This will reboot the unit, taking up to 120 seconds. During this time you will not be able to
communicate with the unit.
If you cannot communicate with the unit after 120 seconds, this could indicate a problem with
the memory update process. Under these circumstances the user should enter "Recovery
Mode", see Section 9 "Recovery Mode".
After the reboot the user should check that the required software image is loaded and
running.
NOTE: Please ensure that you are upgrading the correct units. Units cannot be downgraded.
8.3.7

Spectrum Management

Spectrum Management Selection is the PTP 500 Series Bridge feature that monitors the
available wireless spectrum and directs both ends of the wireless link to operate on a channel
with a minimum level of co-channel and adjacent channel interference.
8.3.7.1
Wireless Channels
The PTP 500 Series Bridge operates using a set of predefined overlapping channels. There
are a different number of channels, depending on the raster mode selected. Each channel
occupies 15 MHz, 10 MHz or 5 MHz of wireless spectrum and is offset in center frequency
from its neighboring channel by 5 MHz. It is important to note that adjacent channels on the
Spectrum management display have a 5 MHz overlap to the adjacent channel.