8.3.11.1 Diagnostic Plotter
New for the PTP 500 Series is the system administration diagnostic plotter facility see Figure
69.
The diagnostic plotter allows the system administrator to view the cascading histogram data
in an easily accessible graphical form. The plot always displays three traces, maximum,
minimum and mean by default. The diagnostic selector allows the user to select the various
categories of histogram.
The histograms that are available are:
Vector Error
Rx Power
Tx Power
Signal Strength Ratio
Link Loss
Rx Data Rate
Tx Data Rate
Aggregate Data Rate
The diagnostic plotter uses a novel time representation in the x-axis which compresses the
timeline of the plot without sacrificing resolution.

Figure 69 - Diagnostic Plotter