7.7.3
Making the PTP 300/500/600 Series Bridge PIDU Plus Connection At The ODU
The following procedure describes how connection is made at the ODU. It is often easier to
carry out this procedure on the ground or a suitable surface prior to mounting the ODU.
Ensure that no power is connected to the PIDU Plus or present on the cable before
connecting the ODU.
Step 1: Assemble the cable as described in
7.7.1 above
Step 3: Screw in the body of the weather
proofing gland and tighten
Should it be necessary to disconnect the PIDU Plus to ODU cable at the ODU, this can be
achieved by removing the weather proofing gland and depressing the RJ45 locking tab with a
small screwdriver as shown below.
Figure 20 - Connecting the PIDU+ to the ODU
63
Step 2: Insert the RJ45 connector making
sure that the locking tab snaps home
Step 4: Screw on the clamping nut and tighten
(Do not over tighten – see Figure 18)
7 Installation