NETGEAR MS510TX User Manual page 294

8-port multi-gigabit smart managed pro switch with two 10g ports
Hide thumbs Also See for MS510TX:
Table of Contents

Advertisement

Table 67. Port Status information (continued)
Field
Transmit Packet Errors
Collision Frames
Reset Counters for All or Selected Interfaces on the Switch
To reset the counters for all or selected interfaces on the switch:
1.
Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2.
Launch a web browser.
3.
In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
The login window opens.
4.
Enter the switch's password in the Password field.
The default password is password.
The System Information page displays.
5.
Select Monitoring > Ports > Port Statistics.
The Port Statistics page displays.
6.
Select which type of interfaces display onscreen:
To display physical ports only, click the PORTS link.
To display LAGs only, click the LAGS link.
To display both physical ports and LAGs, click the All link.
7.
Select one or more interfaces by taking one of the following actions:
To clear the statistics for a single interface, select the check box associated with the
interface, or type the interface number in the Go To Interface field, and click the Go
button.
To clear the statistics for multiple interfaces, select the check box associated with
each interface.
To clear the statistics for all interfaces, select the check box in the heading row.
8.
Click the Clear button.
The selected counters are reset to 0.
Smart Managed Pro Switches MS510TX and MS510TXPP
Description
The number of outbound packets that could not be transmitted because of
errors.
The best estimate of the total number of collisions on this Ethernet segment.
Monitor the System
Access the Switch
294
on page 12.