Mitsubishi MELSEC-F User Manual page 277

Hide thumbs Also See for MELSEC-F:
Table of Contents

Advertisement

APPENDIX
App - 7
(3) FX Configurator-EN (GX Developer) settings
Set the PLC parameters as follows.
(a)
Operation settings
Communication data code
Initial timing
IP address
(b)
Open settings
Protocol
Open system
Fixed buffer
Fixed buffer communication
procedure
Pairing open
Existence confirmation
Host station Port No.
: ASC II (BFM#24 b1: ON)
: Always wait for OPEN (Communication
possible at STOP time) (BFM#24 b8: ON)
: 172.16.56.99 (AC.10.38.63
to 107)
: TCP (BFM#32 b8: OFF)
: Unpassive (BFM#32 b14, b15: 10
: Send (BFM#32 b0: OFF)
: Procedure exist (MC) (BFM#32 b9: OFF,
b10: ON)
: Disabie (BFM#32 b7: OFF)
: No confirm (BFM#32 b1: OFF)
: 10000 (BFM#40)
MELSEC-F
) (BFM#106
H
)
H
App - 7