Mitsubishi MELSEC-F User Manual page 233

Hide thumbs Also See for MELSEC-F:
Table of Contents

Advertisement

11 TROUBLESHOOTING
BFM address
Decimal
(hexadecimal)
440 to 441
(1B8
to 1B9
)
H
H
442 to 443
TCP
(1BA
to 1BB
)
H
H
444 to 445
(1BC
to 1BD
)
H
H
472 to 473
(1D8
to 1D9
)
H
H
474 to 475
UDP
(1DA
to 1DB
)
H
H
476 to 477
(1DC
to 1DD
)
H
H
22640 (5870
)
H
22643 (5873
)
H
22644 (5874
)
H
22645 (5875
)
H
22646 (5876
)
H
22647 (5877
)
H
22649 (5879
)
H
Receive
22650 (587A
)
H
22651 to 22658
(587B
to 5882
)
H
H
22659 to 22662
(5883
to 5886
)
H
H
22663 to 22692
(5887
to 58A4
)
H
H
22693 to 23352
(58A5
to 5B38
)
H
H
23355 (5B3B
)
H
23356 (5B3C
)
H
23357 (5B3D
)
H
23358 (5B3E
)
H
23359 (5B3F
)
H
23361 (5B41
)
H
23362 (5B42
)
H
Send
23363 to 23370
(5B43
to 5B4A
)
H
H
23371 to 23374
(5B4B
to 5B4E
)
H
H
23375 to 23404
(5B4F
to 5B6C
)
H
H
23405 to 23712
(5B6D
to 5CA0
)
H
H
11 - 8
Applicable buffer memory
Received TCP packet count
Received TCP packet count
discarded due to Sum check error
Sent TCP packet total count
Received UDP packet total count
Received UDP packet count
discarded due to Sum check error
Sent UDP packet total count
Number of mails remaining on the
server
Number of normal receives
Number of attached file receives
Number of server inquiries
Number of server transfer errors
Number of error log writes
Error code
Command code
From
Error log block 1
Receive data
Subject
Error log block 2 to 16
(same as error log block 1)
Number of mails normally completed
Number of attached file sends
Number of sends to the server
Number of mails abnormally
completed
Number of error log writes
Error code
Command code
To
Error log block 1
Receive data
Subject
Error log block 2 to 16
(same as error log block 2 to 16)
Ethernet diagnostics
display screen
TCP packet
Status of each
protocol
UDP packet
Number of mails remaining on the server
Number of normal receives
Number of attached file receives
Number of server inquiries
Number of server transfer errors
Number of error log writes
Received e-mail
information
Latest error log
Error log block 2 to 16 (same as error log block 1)
Number of mails normally completed
Number of attached file sends
Number of sends to the server
Number of mails abnormally completed
Number of error log writes
Send e-mail
information
Latest error log
Error log block 2 to 16 (same as error log block 1)
MELSEC-F
Display contents
Total number of receives
Total number of Sum check error
annulments
Total number of sends
Total number of receives
Total number of Sum check error
annulments
Total number of sends
Error code
Command code
From
Date
Subject
Error code
Command code
To
Send date
Subject