1-11. Tension Confirmation
SPEC
(PLAY) 6.0 ± 1gf
(REV) 9.0 ± 2gf
PLAY, REV × 1
MODE
TAPE
63 min M size Blank Tape
TOOL
VFK1145 (Tension Meter)
1. Play back beginning portion of the tape.
2. Insert the tension meter between S3 post and
S4 post. (Refer to figure).
3. Confirm the tension is within specification.
4. Place the unit in REV mode.
5. Insert the tension meter between S4 post and
S5 post.(Refer to figure)
6. Confirm the tension is within specification.
NOTE: Be careful not to give some tape damage.
Play Tension
Rev Tension