Sample Pulse Adjustment; Reset Dc Adjustment - Panasonic AJ-D400P Service Manual

Dvcpro series camera recorder
Table of Contents

Advertisement

1-3. Sample Pulse Adjustment

BOARD
Pulse
SPEC.
NTSC : A = 25.0 ± 1ns, B = 16.0 ± 1ns
PAL : A = 27.5 ± 1ns, B = 16.0 ± 1ns
TEST
TP3001 (SMPL) (CDS Board), TP3 (H2)
ADJUST
VR3 (S PH), VR6 (S W)
M.EQ
Oscilloscope
1. Adjust the VR6 so that the pulse width B (TP3001)
is within specification.
2. Adjust the VR3 so that the phase difference A is
within specification. (Trigger : TP3)
<Note>
1. If the adjustment is not completed even after the
VR is fully turned, keep the VR where it is.
(left end or right end)
50%
TP3 (H2)
TP3001 (SMPL)
50%
A
B

1-4. Reset DC Adjustment

BOARD
Pulse
SPEC.
A = Maximum
TEST
TP3203 (G S/H) (CDS Board)
ADJUST
VR13 (R DC), VR8 (SUB G)
F.NBR.
Open (2000LUX)
CHART
Grayscale Chart
M.EQ
Oscilloscope
1. Set the VR13 to the centre position.
2. Turn the VR8 counterclockwise fully so that the
saturation level depends on R DC.
3. Turn the VR8 clockwise until the saturation level
depends on SUB G.
4. Adjust the VR13 so that the waveform level is
maximized.
5. Install the Head Optical Ass'y (camera unit) again.