Display of marker confirmation screen (marker select function)
The screen for confirming the marker status of the camera can be displayed on the viewfinder screen.
Pushing the <MARKER SEL>/<MODE CHECK/MENU CANCEL> switch on the camera towards the <MKR> side switches between [A] marker display
→ [B] marker display → no display
With the following settings in advance, you can check the angle of view at 14:9 and 4:3 easily by this button, if necessary. As the [A] marker information,
set [14:9] in the main menu → [VF] → [VF MARKER] → [FRAME SIG], and as the [B] marker information, set [4:3] in [FRAME SIG].
Confirmation of return video signal in the viewfinder
The return video signal input to the <SDI IN> terminal can be viewed in the viewfinder while the <RET> button on the lens is held down. To activate this
function, select [CAM RET] in the main menu → [CAMERA] → [SW MODE] → [RET SW].
@
NOTE
t The HD-Y or VBS signals of the <GENLOCK IN> terminal cannot be viewed as return video signals.
Zebra patterns display
The camera can display two types of zebra patterns.
When the <ZEBRA> switch of the viewfinder is set to <ON>, the zebra pattern currently set in the menu is displayed on the viewfinder screen.
Zebra patterns can also be displayed in the video of the monitor output terminal (<SDI OUT2>, <VIDEO OUT>, <HDMI OUT>) according to settings.
The level for displaying zebra patterns can be set in the main menu → [VF] → [VF DISPLAY].
Item
[ZEBRA1 DETECT]
[ZEBRA2 DETECT]
[ZEBRA2]
[SPOT]: The image level from the setting value of [ZEBRA1 DETECT] to the setting value of [ZEBRA2 DETECT] is displayed in the zebra pattern.
Chapter 4 Shooting — Viewfinder status display
Type of marker
Center marker
The aspect ratio currently set at [FRAME SIG] is displayed.
Sets the level of zebra pattern 1 tilting to the right.
[0%]...[109%]
f Factory setting: [70%]
Sets the level of zebra pattern 2 tilting to the left.
[0%]...[109%]
f Factory setting: [85%]
Selects the type of [ZEBRA2].
[ON], [SPOT], [OFF]
f Factory setting: [SPOT]
Video level
[ON]
[109%]
[ZEBRA2 DETECT]
[ZEBRA1 DETECT]
[0%]
Safety zone
Description of settings
[ZEBRA2]
[OFF]
[SPOT]
– 114 –