Modulation Adjustment; Modulation Confirmation - Panasonic AJ-D400P Service Manual

Dvcpro series camera recorder
Table of Contents

Advertisement

5-20. Modulation Adjustment

BOARD
Pulse, Sync
SPEC.
MAX at 5MHz
CAM OUT (75 W terminated)
TEST
VR14 (MOD) (Pulse)
ADJUST
VR201, VR202, VR203 (Sync)
CHART
Immega Chart
M.EQ
Waveform Monitor, EVR
1. Turn the VR14 fully counterclockwise.
2. Set Gain SW to L.
3. Press the [F2] and [3] keys to set the EVR to
[1E][35][00].
4. Open the iris until white level is 80%.
5. Execute AWB function in the A ch.
6. Open the iris until white level is 90%.
7. Turn the VR201 (Sync) counterclockwise fully.
8. Turn the VR201 clockwise until the level At 5MHz
is maximized first.
9. Set shutter to 1/2000.
10. Set Gain SW to M.
11. Repeat from 6 to 8 with VR202 (Sync).
12. Set Gain SW to H.
13. Repeat from 6 to 8 with VR203 (Sync).
14. Set shutter OFF and Gain L.
4MHz
Maximize
5MHz
6MHz

5-21. Modulation Confirmation

BOARD
Pulse
SPEC.
60 ± 5% at 5MHz
CAM OUT (75 W terminated)
TEST
ADJUST
VR2 (CLMP PH) (Pulse)
CHART
Immega Chart
M.EQ
Waveform Monitor, EVR
1. Press the [F2] and [3] keys to set the EVR to
[1E][35][00].
2. Open the iris until white level is 80%.
3. Execute AWB function in the A ch.
4. Open the iris F5.6 – F4.
5. Confirm that the level At 5MHz is within
specification.
6. If not, fine-adjust the VR2. When VR2 is adjusted,
open the iris until white level is 80% and execute
AWB function in the A ch.
7. Confirm that the level at 5MHz is within
specification. (60 ± 10% is accepted only when
VR2 is fully-turned.)
8. When VR2 is adjusted, repeat from Modulation
Adjustment.
9. Finally, set the EVR to [1E][3A][00].

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj-d400pe

Table of Contents