1-21. A/C Head Azimuth and X-value Adjustment.

SPEC.
AS shown in the below figure.
-250us ≤ t1 ≤ +250us
-250us ≤ t2 ≤ +250us
A/C Head each screws
ADJUSTMENT
MODE
Play
TAPE
VFM3582KM, VFM3682KM
1. Playback the X-value alignment tape.
2. Adjust A/C Head Azimuth (refer to Azimuth adjustment procedure) so that the CTL and Lack part of
CUE(t2) is match in the phase.
3. Confirm the lack track of envelope, and select the HSW correspond with it ( The lack track is correspond
HSW high with L ch).
4. Adjust X-value so that the reference of HSW and CTL trigger (select the next trigger at duty 6 to 4
portion: refer to below figure) are match in the phase(t1). To adjust X-value, loosen the screw C and D,
adjust the hole E by VFK0357. After adjustment tighten the screw C and D with 2.5Kg torque. At this
time adjust the phase simultaneously with Azimuth so that the CTL and CUE phase is kept.
5. Hit the top plate ( portion L as shown in below figure ) of A/C Head lightly by a pointed end of Eccentric
driver , then confirm the phase is not shifted finally.
R/P ENV
H_SW
CUE
CTL
5
5
L
t1:CUE phase shift
4
6
6
TEST POINT
M.EQ
TOOL
t2:CTL phase shift
4
5
5
5
TP500:R/P ENV(RF Board)
TP300:R/P HSW (RF Board)
TP505:CUE AUDIO (LCD Board)
TP107:CTL (SERVO Board)
Oscilloscope
VFK0357(Eccentric Driver)
5
5
5