6.2

Procedure before Operation

The flow chart below shows the Non-Protocol Communication setting procedure up until data link:
1.
Check communication specifications
For communication specifications, and communication applicability, refer to Page 154 Specifications.
2.
System configuration and selection.
For system configuration of each PLCs, refer to Page 153 System Configuration.
3.
Wiring
For selection of cables and connection equipment, and wiring example, refer to Page 154 Wiring.
4.
Communication settings
For communication settings of communication device, refer to Page 159 Communication Settings.
5.
Program creation
For detailed explanation of related devices, operation of control line, and program, refer to Page 162 Programming.
*1 For details on operating procedures of GX Works3, refer to the manual below.
GX Works3 Operating Manual
6.3

System Configuration

This section outlines the system configuration required to use non-protocol communication.
You can use up to a maximum of 4 channels (FX5UC is maximum of 3 channels) of non-protocol communication in the CPU
module using the built-in RS-485 port, communication board and communication adapters.
The serial port assignments are fixed to the following numbers, regardless of the system configuration.
■FX5U CPU module
CH4: Communication adapter-2
CH3: Communication adapter-1
CH1: Built-in RS-485 port
CH2: Communication board
Communication device
Built-in RS-485 port
Communication
FX5-485-BD
board
FX5-232-BD
Communication
FX5-485ADP
adapter
FX5-232ADP
*1 Assigned to CH3 or CH4 in order of proximity to CPU module.
*1
Serial port
Important points for selection
CH1
Since it is built-into the CPU module, there is no need to add
equipment.
CH2
Mounted on top of the CPU module, there is no change in the
installation space requirements.
*1
CH3, CH4
Mount the communication adapter to the left of the CPU
module.
■FX5UC CPU module
CH4: Communication adapter-2
CH3: Communication adapter-1
CH1: Built-in RS-485 port
6 NON-PROTOCOL COMMUNICATION
6.2 Procedure before Operation
Overall distance
50 m or less
50 m or less
15 m or less
1200 m or less
15 m or less
153
6