Related Devices; List Of Related Devices; Details Of Related Devices - Mitsubishi MELSEC iQ-F FX5 User Manual

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

4.9

Related Devices

List of related devices

Special relay
Device No.
CH1
CH2
SM8500
SM8510
SM8740
SM8750
R: Read only
Special register
Device No.
CH1
CH2
SD8500
SD8510
SD8502
SD8512
SD8740
SD8750
SD8741
SD8751
SD8742
SD8752
SD8503
SD8513
R: Read only
*1 When SD latch setting is set to "latch", device value can be changed in the program or an engineering tool, and by turning power supply
ON→OFF or by reset, the corresponding function can be operated with the changed value.
*2 With latch settings: Read/write
No latch settings: Read only

Details of related devices

The devices described below are used in MC protocol.
Serial communication error
Turns ON when an error occurs in serial communication. These flags are for check of the serial communication error.
CH1
CH2
SM8500
SM8510
R: Read only
After the devices above turns ON, the error code is stored in the compatible devices below.
CH1
CH2
SD8500
SD8510
Precautions
Do not turn ON or OFF with program or engineering tool.
Serial communication error does not turn OFF even if the communication comes back to normal.
The devices turn OFF when power is turned OFF→ON, reset or SM50 (Error Detection Reset Completion) is turned ON.
4 MC PROTOCOL
88
4.9 Related Devices
Name
CH3
CH4
SM8520
SM8530
Serial communication error
SM8760
SM8770
Station number setting latch
setting valid flag
Name
CH3
CH4
SD8520
SD8530
Serial communication error
code
SD8522
SD8532
Serial communication settings
SD8760
SD8770
Station number settings
SD8761
SD8771
Message system
SD8762
SD8772
Time-out time setting
SD8523
SD8533
Serial communication
operation mode
CH3
SM8520
CH3
SD8520
Description
Turns ON when an error occurs in serial communication.
Turns ON when the SD latch setting of station number setting is
valid.
ON: SD latch setting of station number setting is valid
OFF: SD latch setting of station number setting is invalid
Description
Stores the error code when a serial communication error
occurs.
Stores the setting of the communication parameter.
*1
Sets the station number of a PLC.
Stores the setting of the message system.
These devices set the evaluation time for error when receiving
of data from the counterpart equipment is interrupted.
Stores the communication type being used.
CH4
Description
SM8530
Turns ON when an error occurs in serial
communication.
Devices do not go OFF even when normal
communication is restored.
CH4
Name
SD8530
Serial communication error
code
R/W
R
Description
When a serial communication error occurs,
the error code is stored.
R/W
R
R
R/W
R
R
*2
R
R
R